6-14. Error Code
A. R-Sensor Error
1) Error Code : R1
① R-Sensor Open : It happens when R-Sensor is sensing less than -45℃
2) Condition :
② R-Sensor Short : It happens when R-Sensor is sensing more than 50℃
3) release : When R-Sensor is sensing from -45 to 50℃.
B. RT-Sensor Error
1) Error Code : Rt
① RT-Sensor Open : It happens when RT-Sensor is sensing less than -45℃
2) Condition :
② RT-Sensor Short : It happens when RT-Sensor is sensing more than 50℃
3) release : When RT-Sensor is sensing from -45 to 50℃.
C. D-Sensor Error
1) Error Code : D1
① D-Sensor Open : It happens when D-Sensor is sensing less than -45℃
2) Condition :
② D-Sensor Short : It happens when D-Sensor is sensing more than 50℃
3) release : When D-Sensor is sensing from -45 to 50℃
D. R-Door Error
1) Error Code : dr
2) Condition : It happens when the system senses R-Door opens more than 1 hour
3) release : If R-Door switch (close) is sensed, the error is terminated automatically
E. Cycle Error
1) Error Code : C1
2) Condition : When D-Sensor is more than -5°C, Comp operates over 3 hours
3) release : When Comp is off, D-Sensor is less than -5°C.
* When D-Sensor is normal operation, "C1" Error can be checked.
F. Return Defrost Error
1) Error Code : F3
2) Condition : Return to next limit defrost time.
3) release : Completion of defrost returned by D-Sensor.
* When D-Sensor is normal operation, "F3" Error can be checked.
NEO-V SVC MANUAL
38

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Neo-v rcp36 seriesNeo-v rct33 seriesNeo-v rct36 series