6-12. Mode Control
The mode can be entered within 2 hours.
After 2 hours, The mode enterable environment is activated by pushing "TEMP +
"FUNC" Key for 10 seconds.
A. As Forced Defrost Mode
1) How to enter
① How to enter through Key Operation
- by press "TEMP" button for continuously and "FUNC" button 5 times.
② How to enter through Main PCB Test Switch
- See part of the "Test Switch" in "Function Switch Control" Chapter.
2) Operation
- Process: same as General Defrost Mode except "PRE-COOL"
- Heater is on Initial 60 seconds even though the temp.
(for TEST)
CONTENTS
Limited Time
Each stage
Release conditions
Comp
Parts.
Defrost-HTR
F- Fan
3) Mode release : Auto closed after performing functions.
B. Short Circuit Test Mode
1) How to enter : See part of the "Test Switch" in "Function Switch Control" Chapter.
(It is available to restart the test and it'll be take 30 hours.)
2) Operation
- COMP & FAN will be on independent of the operating condition.
- There is no defrost mode on this test.
3) Mode release : after the limit test time 30 hours passes.
HTR On
60 minutes
1. Limited Time
2. D-S > 10℃
Off
On
Off
34
NEO-V SVC MANUAL
Pause
Fan Delay
10 minutes
1 minutes
Limited Time
Limited Time
Off
On
Off
Off
Off
Off

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Neo-v rcp36 seriesNeo-v rct33 seriesNeo-v rct36 series