6-6. Defrost Control
- RT / D-Sensor
- Comp operation time / Real Time
- Comp operation rate / Door Open Time
A. Initial Defrost
CONTENTS
If the temperature at the D-sensor is under 3.5°C, Defrost Mode starts.
Inrush conditions
When D-Sensor Error is happened, the initial defrost function isn't performed .
Each stage
Release conditions
Mode release
Auto closed after performing functions
Input
PreCool
- Exception
① D-Sensor > 10℃
Heater On
② after 60 minutes
Pause
- after 10 minutes
Fan Delay
- after 1 minute
NEO-V SVC MANUAL
Output
- Defrost Heater On/Off Operation
EXPLANATION
26