Connecting The Power Supply; Resetting The Netcommander Kvm System; Rackmount Considerations; Rackmounting The Netcommander Kvm System - Tripp Lite NetCommander B072-008-1 Owner's Manual

8- and 16-port cat5 rackmount kvm switches
Hide thumbs Also See for NetCommander B072-008-1:
Table of Contents

Advertisement

Installation

Connecting the Power Supply

1. Plug in the KVM. Use only the power cord supplied with the unit.
2. Switch ON the computers.
Resetting the KVM Switch
To reset the KVM switch, press both Select buttons on the front panel simultaneously. The
Server Interface Units are unaffected by this reset.

Rackmount Considerations

Ambient Operating Temperature
The ambient operating temperature in the rack may be an issue and is dependent upon the
rack load and ventilation. When installing in a closed or multi-unit rack assembly, make sure
that the temperature will not exceed the maximum rated ambient temperature.
Airflow
Ensure that the airflow within the rack is not compromised.
Circuit Overloading
When connecting the equipment to the supply circuit, consider the effect that overloading of
circuits might have on over-current protection and supply wiring.
Reliable grounding of rack-mounted equipment should be maintained.
Rackmounting the NetCommander KVM
Use the L-shaped brackets and screws provided to mount the KVM in a server rack as
illustrated below.
(continued)
Figure 7 Connecting the L-shaped bracket
7