High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding
with repair work. Failure to heed this caution may result in electric shocks.
17.2 CS-XE18WKUAW CS-XE24WKUAW
17.2.1
Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal
Procedures
17.2.1.1
To Remove Front Grille
17.2.1.2
To Remove Electronic Controllers
2. Remove 3 caps and 4 screws at the
bottom of discharge vane and 1 screw
at the front grille.
WARNING
3. Hold both sides of the front grille and
remove it by pulling up and toward
yourself gently.
1. Lift to open the horizontal vane
gently.
Figure 1
2 hooks
Figure 2
8. Pull out the electronic
controller.
5. Detach the Earth wire screw,
lead wires AC306 (Black) and
AC304 (Red) from the terminal board.
7. Remove screw to remove
terminal board complete.
6. Detach the indicator
connector from indicator
complete.
Figure 3
124
4. Removing the control
board cover by
releasing 2 hooks.