Fan Motor - Daikin FTKS09JV2S Service Manual

Removal procedure, 2.0/2.2/2.5/2.8/3.5/3.6/4.1/4.2/4.6/ 5.0 kw class, 7000/9000/12000/15000 btu/h class
Table of Contents

Advertisement

Fan Motor

10.Fan Motor
Warning
Step
1
Remove the 2 screws
and remove the right
side plate.
2
Remove the 2 screws
and remove the fan
motor fixing plate.
3
Loosen the lock screw
and remove the fan
motor.
4
Press the bearing
ASSY inward.
18
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Right side
plate
(R21147)
Fan motor fixing plate
(R21148)
Lock screw
Fan motor
(R8120)
(R8121)
Si041252EE
Points
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm
(0.2 inch) of play between
the side face of the rotor and
the bottom frame.
Side face of
Side face of rotor
bottom frame
5 mm (0.2 inch)
(R9582)
(1) Insert the fan motor with
approx. 5 mm (0.2 inch) left.
(2) Tighten the screw until it
stops. Then turn the screw in
one scroll.
(3) Move the fan rotor and
confirm the fan motor and
the fan rotor are installed
appropriately.
(4) If appropriate, tighten the
screw completely.
(5) If not appropriate, go back to
(1).
Removal Procedure
(R18879)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents