Electrical Box - Daikin FTKS09JV2S Service Manual

Removal procedure, 2.0/2.2/2.5/2.8/3.5/3.6/4.1/4.2/4.6/ 5.0 kw class, 7000/9000/12000/15000 btu/h class
Table of Contents

Advertisement

Electrical Box

6. Electrical Box
Warning
Step
1
Remove the screw and
remove the wire fixture.
2
Remove the 4 screws
on the terminal board
and disconnect the
connecting wire.
3
Disconnect the
connector [S1].
4
Disconnect the
connector [S41].
5
Release the harness for
the swing motors from
the hook.
8
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Electrical box
Hook
Terminal
board
Connecting
wire
Wire
fixture
(R18696)
[S1]
(R13499)
[S41]
(R18694)
(R18695)
Si041252EE
Points
For U.S. models
When reassembling, make
sure that the connecting wire
is passed through the
conduit hole at the bottom of
the unit.
[S1]: fan motor
[S41]: swing motors
When reassembling, be sure
to put the harness for the
swing motors behind the
hook.
Removal Procedure