Vertical Blade Assys - Daikin FTKS09JV2S Service Manual

Removal procedure, 2.0/2.2/2.5/2.8/3.5/3.6/4.1/4.2/4.6/ 5.0 kw class, 7000/9000/12000/15000 btu/h class
Table of Contents

Advertisement

Vertical Blade ASSYs

5. Vertical Blade ASSYs
Warning
Step
1. Remove the fan guards.
1
Unfasten the 2 hooks at
the lower part of the fan
guard with a flat
screwdriver.
2
Remove the fan guard.
3
Remove the other fan
guard in the same way.
2. Remove the vertical blade
ASSYs.
1
Detach the pivot from
the interlock shaft for
vertical blades with a
flat screwdriver.
2
Remove the interlock
rod.
6
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Vertical blade ASSY
Interlock rod
Some models have no fan
guard.
(R13751)
(R8079)
Pivot
Interlock
shaft
(R13092)
(R13093)
Si041252EE
Points
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents