11 Fault Messages & Troubleshooting; Overview - Henny Penny FlexFusion ELECTRIC SPACESAVER PLUS FSE-610 Service Instructions Manual

Hide thumbs Also See for FlexFusion ELECTRIC SPACESAVER PLUS FSE-610:
Table of Contents

Advertisement

Fault messages & troubleshooting
11 Fault messages & troubleshooting

11.1 Overview

No.
Fault message displayed
694
Cooking sensor defective
695
699
Core temperature sensor defective
700
701
Fan defective. Cooking program was canceled
1481
Fan defective. Operation not possible (1481)
709
Water pressure too low
424
The water pressure is too low; cleaning has been
paused.
710
Vapour sensor defective
1478
The operating unit battery is empty
FAN_ID23
Fan error: Attempt to restart
ID18
Excess temperature in the cooking chamber
ID73
MMI_ID50
Critical temperature in the electronics
1520
The NFC tag is not present
SA_ID
Fault in moisture removal control. Limited
operation
TMP_ID2
Overtemperature in control
TMP_ID72
Risk of frost
MMI_ID51
Unit was restarted after power failure
50
Section
Cooking chamber sensor defective (694, 695)
Core temperature sensor defective (699, 700)
Fan defective. Cooking program was cancelled
(701)
Fan defective. Operation not possible (1481)
Water pressure too low (709)
Water pressure during WaveClean too low
Water vapor sensor defective (710)
The operating unit battery is empty
FAN_ID23: Fan error: Attempt to restart
Excess temperature in the cooking chamber
(ID18, ID73)
Critical temperature in the electronics (MMI_ID50)
The NFC tag is not present
Fault in moisture removal control. Limited
operation
Overtemperature control (TMP_ID2)
Risk of frost (TMP_ID72, MMI_ID51)
Unit was restarted after power failure