5. LPS: Lightning protection system, refer to the following options:
AC side, nominal discharge current 20KA, second grade lightning protection, protection voltage 2.5KV
DC side, nominal discharge current 20KA, second grade lightning protection, protection voltage 3.2KV
6. The wiring distance between the inverter and the distribution box should be at least 5 meters.
7. Utility: Referred to as "grid" in this manual, i.e. the media your electric power company provides power
to your place. Please note that Inverter can only be connected to low-voltage systems (namely, 220/230Vac,
50/60Hz).

7 Operation

Product Overview
Enclosure Lid
LCD
16
20
23
28
31
33
25
32
32
40
50
50
19
KEY