  • Page 1 GP-37W3 Series User Manual (Pro-Designer Compatible)
  • Page 2 Preface Thank you for purchasing Pro-face’s GP-37W3 Series Graphic Control Panel (hereafter referred to as either the “GP” or the “GP unit”). Please read this manual carefully as it explains, step by step, how to use the GP correctly and safely.
  • Page 3: Table Of Contents

    Table of Contents Preface ........................1 Table of Contents ...................... 2 Essential Safety Precautions ................... 4 General Safety Precautions ..................7 GP-37W3 Series Models ..................9 Package Contents ..................... 9 UL/c-UL(CSA) Approval ..................10 CE Marking ......................11 CNS Standards ......................11 Documentation Conventions ..................11...
  • Page 4: Preface

    5.2.2 SELF TEST - details ................5-4 CHAPTER 6 MAINTENANCE 6.1 Regular Cleaning ................... 6-1 6.1.1 Cleaning the Display ................6-1 6.1.2 Installation Gasket Check/Replacement ..........6-1 6.2 Periodic Check Points ................... 6-3 6.3 Changing the Backlight ................6-3 GP-37W3 Series User Manual...
  • Page 5: Essential Safety Precautions

    GP-37W3 Series User Manual...
  • Page 6 If the battery is incorrectly replaced, the bat- tery may explode. To prevent this, please do not replace the battery yourself. When the battery needs to be re- placed, please contact your local GP distributor. GP-37W3 Series User Manual...
  • Page 7 GP unit malfunction. • Be careful that metal filings and wiring debris do not fall inside the GP, since they can cause a fire, GP unit mal- function, or operation error. GP-37W3 Series User Manual...
  • Page 8: General Safety Precautions

    • Do not store or use the GP where chemicals (such as organic solvents, etc.) and acids can evaporate, or where chemicals and acids are present in the air. • Do not use paint thinner or organic solvents to clean the GP. GP-37W3 Series User Manual...
  • Page 9 • Do not display any single screen for a long period of time. Try to periodically change the screen display. *1 If the GP’s voltage is at the very low end of its allowable range, it may effect the intensitly of contouring. GP-37W3 Series User Manual...
  • Page 10: Gp-37W3 Series Models

    Preface GP-37W3 Series Models The GP-37W3 Series refers to the following GP model number: Series Model Name Model Type Comments GP37W3-BG41-24V CE Marked, UL/c-UL (CSA), CNS Approved unit GP-37W3 Series GP-37W3B Package Contents The GP’s packing box contains the items listed below. Please check to confirm that all items shown below have been included.
  • Page 11: Ul/C-Ul(Csa) Approval

    OFF before replacing or wiring modules. 5. WARNING: Explosion hazard – confirm that the power supply has been turned OFF before disconnecting equipment, or confirm that the location is not subject to the risk of explosion. GP-37W3 Series User Manual...
  • Page 12: Ce Marking

    Indicates steps in a procedure. Be sure to perform these steps in 1) , 2) the order given. Refers to useful or important supplemental information. Provides useful or important supplemental information. Screen Editor Indicates the Pro-Designer Ver. 4.0 screen editor software. Abbreviation for Programmable Logic Controller. GP-37W3 Series User Manual...
  • Page 13 Memo GP-37W3 Series User Manual...
  • Page 14: System Design

    Terminal Adapter GP070-CN10-O Mitsubishi PLC A, Q, C, FX Series’ 2 Port Adaptor II 2 Port Adaptor II GP070-MD11 Cable GP070-MDCB11 Mitsubishi PLC A-Series Program Port I/F Cable GP430-IP10-O Mitsubishi PLC FX-Series Program Port I/F Cable GP430-IP11-O GP-37W3 Series User Manual...
  • Page 15 Programming Port Personal Computer Interfaces Printer Interface *1 For range of compatible PCs refer to the following manual. Pro-Designer On-line Help *2 For information about compatible PLC types and software, please refer to Pro-Designer On-line Help GP-37W3 Series User Manual...
  • Page 16: Accessories

    Programming Port I/F GP430-IP10-O Programming Console. Simultaneous cable use of program console, however, is not Mitsubishi FX Series possible. Programming Port I/F GP430-IP11-O cable *1 For detailed information about range of connectable PLCs. Pro-Designer On-line Help GP-37W3 Series User Manual...
  • Page 17 Model No. Description Installation fastener Fasteners to attach the GP to a panel. GP070-AT01 Installation gasket Provides a moisture resistant seal when installing the GP. Same as the seal GP37W2-WP00-MS included in the GP’s original equipment package. GP-37W3 Series User Manual...
  • Page 18: Chapter 2 Specifications

    10Hz to 57Hz 0.035mm, 57Hz to 150Hz 4.9m/s X, Y, Z directions for 10 times (80min.) Noise Voltage: 1000Vp-p Noise Immunity Pulse Duration: 1x10 sec. (via noise simulator) Arise Time: 1ns Electrostatic Discharge 6kV (complies with IEC 61000-4-2 Level 3) Immunity GP-37W3 Series User Manual...
  • Page 19: Structural

    If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, you need to replace the installation gasket regularly. GP-37W3 Series User Manual...
  • Page 20: Functional Specifications

    Both height and width can be expanded 1, 2, 4, or 8 times. Font Sizes 8X8, 8X16, 16X16 and 32X32 dot fonts Text Sizes Resistive Film - 16X12 Keys/Screen (1 or 2 point touch) Touch Panel GP-37W3 Series User Manual...
  • Page 21: Memory And Clock

    Parity: None, Odd or Even Data T ransmission Speed: 2400 to 115.2kbps Asynchronous TT L level nonprocedure command I/F For connecting the Data Transfer cable when creating data from Tool Connector the Pro-Designer screen editor software. GP-37W3 Series User Manual...
  • Page 22: Interface Specifications

    XM2Z-0071<made by OMRON> Use rough metric type M2.6x0.45 p threads used to secure the cable’s set screws. Recommended Cable: CO-MA-VV-SB5P x 28AWG <made by HITACHI Cable Ltd.> To confirm your PLC’s connection specifications Pro-Designer On-line Help GP-37W3 Series User Manual...
  • Page 23 SG/GND (Signal Ground) terminals. If this is not done, the RS485(RS422) circuit may be damaged. • Pin 14 (VCC) DC5V output is not protected. To prevent damage or unit malfunction, be sure to use only the designated level of current. GP-37W3 Series User Manual...
  • Page 24: Part Names And Functions

    The input and ground terminals for the power cable. E: Serial Interface Used for the RS-232C and RS-422 (Serial) cables. Is connected to the Host (PLC). F: Tool Connector The Data Transfer cable can be connected here. GP-37W3 Series User Manual...
  • Page 25: Dimensions

    For detailed dimension information, please contact your local GP distributor. Unit: mm [in.] 191.2 [7.53] Front Side 58 [2.28] 207 [8.15] 6 [0.24] The following drawing shows the GP-37W3 Series unit with installation fasteners. 125 [4.92] 62.5 [2.46] 207 [8.15] GP-37W3 Series User Manual...
  • Page 26: Installation Fasteners

    Chapter 2 - Specifications 2.5.2 Installation Fasteners Unit: mm [in.] 31 [1.22] 16 [0.63] 19.5 [0.77] 2.5.3 GP Panel-Cut Dimensions Unit: mm [in.] +0.04 7.54 191.5 4-R3 or less GP-37W3 Series User Manual...
  • Page 27 Memo 2-10 GP-37W3 Series User Manual...
  • Page 28: Chapter 3 Installation And Wiring

    • Check that the installation panel or cabinet’s surface is flat, in good condition and has no jagged edges. • Panel thickness should be from 1.6mm (0.06in.) to 5mm (0.2in.). 1.6mm(0.06in.) to 5mm (0.2in.) Decide the panel’s thickness based on the level of panel strength required. GP-37W3 Series User Manual...
  • Page 29 You may need to use forced air cooling (fan, A/C) to ensure the ambi- ent operating temperature is 40 C or below. • When installing the GP vertically, orient the unit so that the Power Terminal Block is vertical, not horizontal. GP-37W3 Series User Manual...
  • Page 30 Two (2) additional slots on both sides of the GP unit can be used, if greater strength is needed. If these are used, additional (optional) fasteners will be required. Panel hook 3. Slide the mounting bracket back. GP-37W3 Series User Manual...
  • Page 31 Excessive tightening may damage the GP or the panel. A torque of only 0.5 to 0.6 N•m is required to ensure a waterproof seal. Depending on the condition of the panel, increasing the number of the mounting brack- ets may increase the level of water resistance. GP-37W3 Series User Manual...
  • Page 32: Wiring Cautions

    Terminals as shown above and re- Rear of GP-37W3 attach the screws. (Check each wire to make sure the connections are Crimp-on Ring correct and only 0.5 to 0.6 N•m of Terminals force.) 4. Re-attach the Terminal Strip’s clear plastic cover. GP-37W3 Series User Manual...
  • Page 33: Grounding

    If this is not possible, use a shielded cable and connect the shield to the GP’s frame. *1 Use a grounding resistance of less than 100 Ω and a 2mm or greater thickness wire, or your country’s applicable standard. For details, contact your local GP distributor. GP-37W3 Series User Manual...
  • Page 34: Tool Connector

    The GP’s Data Transfer Cable can be attached to the GP’s side face Tool Connector. WARNINGS Before unplugging any connector(s) from the GP, be sure the GP’s power cord is unplugged from the main power supply. GP Side view Tool Connector GP-37W3 Series User Manual...
  • Page 35 Memo GP-37W3 Series User Manual...
  • Page 36: Chapter 4 Settings

    Pro-Designer Runtime will restart and the [Set- tings Menu] will appear. 3. In this mode, the two tabs, [Offline] and [System] are available. Simply touch the desired tab to bring up those settings. The following screen shows the [Offline] area’s selections. GP-37W3 Series User Manual...
  • Page 37: Offline

    Chapter 4 - Settings Offline - Network - Self Test - Buzzer - OP. Switch - Backlight System - Stylus - Language - Date/Time - Ver. Info. - Restart - Memory GP-37W3 Series User Manual...
  • Page 38 Chapter 4 - Settings 4.1.1 Offline Network This cannot be set with GP-37W3 Series units. Touch Buzzer The following buzzer sound settings are available. The factory setting is [Press Touch Object]. • [None] Selecting this will turn the buzzer off.
  • Page 39 4. To automatically turn the backlight off after a specified period of time, touch the [Wait] selection and set the “idle time” period. Self Test Performs the GP unit’s self test. For details, see 5.2 Self Test. OP. Switch This setting item is for GP2000H Series units only. GP-37W3 Series User Manual...
  • Page 40 Designates the language used with System screens and User Applications. Setting Procedure 1. In the [Settings] menu, touch the [System] tab. 2. Touch the [Language] icon. 3. Touch/select the desired language for the [System] and [User Application] items. GP-37W3 Series User Manual...
  • Page 41 Chapter 4 - Settings Memory Displays the total amount of memory, and the amount of memory currently being used. Setting Procedure 1. In the [Settings] menu, touch the [System] tab. 2. Touch the [Memory] icon. GP-37W3 Series User Manual...
  • Page 42: Chapter 5 Troubleshooting

    When a problem occurs, be sure to first read each checklist item and follow the instructions given. If this does not solve the problem, please contact your local GP distributor. When a problem cannot be solved For hardware and software problems, contact the distributor where you bought the GP unit. GP-37W3 Series User Manual...
  • Page 43: No Display

    Designer? Is the Device/PLC connection cable Refer to the Device/PLC s manual and correctly connected? correctly connect the cable. See 3.2 Wiring Cautions Did the above procedure correct the If not, -> Hardware problem problem? GP-37W3 Series User Manual...
  • Page 44: Self Test

    - Disp Pattern - Touch Panel *1*2 - COM 1 - COM 2 - Video Memory *1 This item must be prepared by the user (cable, connector, etc.). *2 Cannot be used with GP-37W3 Series units. GP-37W3 Series User Manual...
  • Page 45: Self Test - Details

    This item is used to check video memory (memory used for screen display). Use this feature when your screen display is not correct. This result of this test will be either [OK] (no problem) or [NG](problem). *1 Cannot be used with GP-37W3 Series units. GP-37W3 Series User Manual...
  • Page 46: Chapter 6 Maintenance

    Attaching the Installation Gasket 1. Place the GP on a level surface with its display facing down. 2. Remove the gasket. 3. Insert the new water-resistant gasket. Make sure that the grooved sides face the top and bottom. GP-37W3 Series User Manual...
  • Page 47 • The upper surface of the gasket should protrude approximately 2mm out from the groove. Be sure to check that the gasket is correctly inserted before installing the GP into a panel. Seam GP-37W3 Series User Manual...
  • Page 48: Periodic Check Points

    The service life of the backlight is as follows (The period when the brightness decreases to about half the brightness of a new product after continuous illumina- tion at normal temperature): 30,000 hours (Approx. 2.8 years) For backlight replacement, contact your local GP distributor. GP-37W3 Series User Manual...
  • Page 49 Memo GP-37W3 Series User Manual...

This manual is also suitable for:

Gp-37w3bGp37w3-bg41-24v

Table of Contents