• When connecting the GP's power cord to the GP, be sure the cord has
first been unplugged from the power outlet to prevent the possibility of
an electric shock.
• With the exception of changing the GP's backlight, do NOT open the
GP's case, since high voltage runs through the GP and touching an in-
ternal part can lead to an electric shock.
• Do not use power beyond the GP's specified voltage range. Doing so
may cause a fire or an electric shock.
• Do not modify the GP's design, since it may lead to a fire or an electric
shock.
• Do not use the GP in an environment where flammable gases are present,
since operating the GP may cause an explosion.
• The GP uses a lithium battery for backing up its internal clock data. If
the battery is incorrectly replaced (i.e. its + and — sides are reversed),
the battery may explode. When changing the battery, please contact
your local GP distributor.
• Do not use GP touch panel switches in life-related or important disaster
prevention situations. For safety related switches, such as an emer-
gency switch, be sure to use a separate mechanical switch.
• To prevent operator injury or machine damage, be sure to design your
machine operation system so that the machine will not malfunction due
to a communication fault between the GP and its host controller.
To Prevent From Damage:
• Do not strike the GP's touch panel with a hard or heavy object, or press
on the touch panel too strongly since it may damage the display.
• Do not install the GP where the temperature will exceed its specified range.
• Be sure that water, liquids or metal particles do not enter the GP, since
it may cause a malfunction or a short circuit.
• Avoid installing the GP where sudden, large changes in temperature
may occur. These changes may cause condensation to form inside the
unit, possibly causing a malfunction.
• To prevent excessive heat from building up inside the GP, do not in-
stall it where its ventilation holes may be blocked. Also, do not install
or store the GP near high temperature equipment.
• Do not install or store the GP where direct sunlight or high levels of dust exist.
• Since the GP is a precision instrument, do not install or store it where
either strong shocks or excessive vibration may occur.
• Do not install or store the GP in an area containing chemicals or chemical
fumes.
• Do not use paint thinner or organic solvents to clean the GP's case or
screen.
• Due to the danger of unforseeable accidents, be sure to back up all data regu-
larly.
• After turning this unit OFF, be sure to wait a few seconds before turning
ON again. If the unit is started within a few seconds, it may not start up
correctly.
WARNING

Advertisement

Table of Contents
loading

Summary of Contents for Pro-face GP377R-TC11-24V

  • Page 1 WARNING • When connecting the GP's power cord to the GP, be sure the cord has first been unplugged from the power outlet to prevent the possibility of an electric shock. • With the exception of changing the GP's backlight, do NOT open the GP's case, since high voltage runs through the GP and touching an in- ternal part can lead to an electric shock.
  • Page 2: Package Contents

    The following items are included in the GP's package. Before using the GP, please confirm that all items shown here are present. GP Unit Installation Guide(1) <This Guide> (GP377R-TC11-24V ) GP377R-TC11-24V Installation Guide Installation Guide Installation fasteners (4) This unit has been carefully packed, with special attention to quality. However, should you find anything damaged or missing, please contact your local GP distributor imme- diately.
  • Page 3 GP-377R Parts Names and Functions A: Display Displays User-created screens and host (PLC) data. GP377R-TC11-24V TFT type LCD B: Touch Panel Performs screen change operations and sends data to the host (PLC). C: Status LED Color changes depending on the unit's status.
  • Page 4: Serial Interface

    Serial Interface This interface is used to connect the GP to the host (PLC), via either an RS-232C or RS-422 cable. Pin # Signal Name Condition Frame Ground Send Data (RS-232C) Receive Data (RS-232C) Request to Send (RS-232C) Clear to Send (RS-232C) No Connection Signal Ground Carrier Detect (RS-232C)
  • Page 5 Since pin #14 is not protected, be sure to use it only within its rated range. When making a cable, please be aware of the following: <For RS-422 Connectors> • The following pairs of pin #'s must be connected (shorted): #18 (CSB) <->...
  • Page 6: Installation

    Installation Follow the steps given below when installing the GP unit. Confirm the Moisture Resistant Gasket’s Seating It is strongly recommended that you use the gasket. When seating the gasket, Moisture resistant place the GP on a level surface with the gasket display panel facing downward.
  • Page 7 GP. • The GP377R-TC11-24V is designed to use only DC24V input. Any other power level can damage both the GP and the power supply. • Be sure to reattach the Power Terminal's clear plastic cover after con- necting the Power Cord's power terminals.
  • Page 8: Power Supply Precautions

    Power Supply Precautions Be aware of the following items when attaching the power cord terminals to the GP's power terminal block. • When operating the GP where large power fluctuations will occur, install a constant voltage transformer. • When attaching an expansion unit to the GP, be sure to read the expansion unit's Installation Instructions.

Table of Contents