Memory And Clock; Interfaces - Pro-face GP-37W3 Series User Manual

Pro-designer compatible
Table of Contents

Advertisement

Chapter 2 - Specifications

2.2.2 Memory and Clock

Internal Clock Accuracy
*1
A Lithium battery's lifetime is:
When used for backup:
*2
The GP's internal clock has a slight error. At normal operating temperatures
and with the GP's power turned OFF, i.e. in "backup mode", the degree of
error is 65 seconds per month. Variations in operating conditions and battery
life can cause this error to vary from -380 to +90 seconds per month.
For systems where this degree of error will be a problem, the user should be
sure to monitor this error and make adjustments when required.

2.2.3 Interfaces

Serial Interface
Tool Connector
2-4
Application
10 years when the battery's ambient temperature is under 40
4.1 years when the battery's ambient temperature is under 50
1.5 years when the battery's ambient temperature is under 60
Approximately 60 days, with a fully charged battery
Approximately 6 days, with a half-charged battery
Asynchronous Transmission Method:
RS232C/RS422
Data Length: 7 or 8 bits
Stop Bit: 1 or 2 bits
Parity: None, Odd or Even
Data T ransmission Speed: 2400 to 115.2kbps
Asynchronous TT L level nonprocedure command I/F
For connecting the Data Transfer cable when creating data from
the Pro-Designer screen editor software.
4MB FEEPROM
+ 65 seconds/month (at 25
GP-37W3 Series User Manual
*1 *2
o
C)
o
C
o
C
o
C

Advertisement