KX-NS500AG
4.2.2.
Main Unit Mother Board
Fig.3 shows detail block diagram of Mother Board, and each function of Base is described in Table.5.
+15V, GND
Fig.3 Main Unit Mother Board Block Diagram
Table.5 Main Unit Mother Board Function Description
Device/Function Block
PLD1(EXT_PLD)
PLD2(CO_PLD)
SLIC/CODEC
DSP(CO)
DPT I/F
4.2.3.
SLIC/CODEC (SLC) Block
Refer to Service Manual of KX-NS5173/KX-NS5174.
4.2.4.
DSP (LCOT) Block
Refer to Service Manual of KX-NS5180.
4.2.5.
DPT I/F Block
Refer to Service Manual of KX-NS5170/KX-NS5171/KX-NS5172.
INT(2)
PLD1
( EXT_PLD)
INT
PLD2
(CO_PLD)
Extension option
Connector
Trunk option
Connector
VBAT
DC/DC
FAN_ALM
FAN I/F
15
Connector
12V
ACALM, DCALM
POWER I/F
Connector
PLD1 controls and monitors SLIC/CODEC LSI of each analog line port.
PLD2 controls the trunk controller DSP which is used in each analog trunk port.
SLIC/CODEC is exclusive LSI which is used for analog line interface.
1) Line interface power supply
2) Dial pulse detection
3) DTMF receiver / Caller ID generation
4) Bell signal generation
5) Hooking detection / Ringtrip detection
6) 2W/4W conversion
7) CODEC function
DSP(CO) is exclusive LSI which is used analog trunk port.
1) Dial pulse generation
2) DTMF signal generation / Caller ID detection
3) Bell signal detection
4) CPC signal detection
5) 2W/4W conversion
6) CODEC function
DPT I/F is Digital Line Interface.
6
SLIC/CODEC bus (SPI)
INT_SLIC
INT_EXT
INT_CO
IIO bus
INT_DSP
TDM Highway bus
DPT - I/F
+3.3 V, GND
+15V, GND
+40V, GND
Description
10
SLIC/CODEC(2ch)
AFE
RJ45
SLIC/CODEC(2ch)
AFE
SLIC/CODEC(2ch)
AFE
RJ45
SLIC/CODEC(2ch)
AFE
SLIC/CODEC(2ch)
AFE
RJ45
SLIC/CODEC(2ch)
AFE
SLIC/CODEC(2ch)
AFE
RJ45
RJ45
SLIC/CODEC(2ch)
AFE
SLT2
SLT1
RJ45
DSP
AFE
MOH
(2ch)
PAG
CO4-CO5
Dial Pulse, CPC DET
RJ45
DSP
AFE
MOH
(2ch)
PAG
CO2-CO3
Dial Pulse, CPC DET
RJ45
DSP
AFE
MOH
(2ch)
PAG
Dial Pulse, CPC DET
CO1-CO2
DPT
I/F
RJ45
(2ch)