Offset Constant; Temperature Setback - Pace Sodrtek ST 145 Operation And Maintenance Manual

Desoldering system
Table of Contents

Advertisement

Temperature Limit (up to 482°C, 900°F). Press and release the Program Key to proceed
to the next step.
c) Press and release the Scroll Down
Limit. Press and release the Program (
10. The LED Display now shows the stored default Low ("Lo") Temperature
Limit with the display alternating to show "Lo" and the stored limit.
Choose one of the following:
a) Press and release the Program (
Temperature Limit (204°C, 400°F min.).
b) Press and release the Scroll Up
Press and release the Program (
c) Press and release the Scroll Down
Limit. Press and release the Program (

Offset Constant

11. The LED Display now shows the stored Offset Constant with the display alternating to show
"OF" and the stored Offset Constant. Choose one of the following:
a) Press and release the Program (
stored Offset Constant.
b) Press and release the Scroll Up
Offset Constant of 0-133°C (0-240°F) can be stored. Press and release the Program (
) Key to proceed to the next step.
c) Press and release the Scroll Down
Press and release the Program (
NOTE: If the attached handpiece is disconnected when the system is powered up, any
stored Offset Constant is reset to zero. The Offset Constant must be entered again
in the Set-Up Mode.

Temperature Setback

12. The LED Display now shows the stored Temperature Setback time
"S-X" (x=0 thru9). Time is shown as tens of minutes (e.g., "S-
3" equals 30 minutes). A display of "S- 0" indicates that Setback is
disabled. Choose one of the following:
a) Press and release the Program (
Setback time.
b) Press and release the Scroll Up
Temperature Setback time. Press and release the Program (
next step.
c) Press and release the Scroll Down
Temperature Setback time. Press and release the Program (
next step.
©2004 PACE Inc., Annapolis Junction, Maryland
All Rights Reserved
Key to decrease the stored High Temperature
) Key to proceed to the next step.
) Key to keep the stored Low
Key to increase the stored Low Temperature Limit.
) Key to proceed to the next step.
Key to decrease the stored Low Temperature
) Key to proceed to the next step.
) Key to keep the currently
Key to increase the stored Offset Constant. An
Key to decrease the stored Offset Constant.
) Key to proceed to the next step.
) Key to keep the currently stored Temperature
Key to enable and/or increase the stored
Key to decrease or disable the stored
as
) Key to proceed to the
) Key to proceed to the
Page 9 of 22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sodrtek st 145e

Table of Contents