1. Air Hose To Handpiece Connection
a) Attach one end of a 137cm (54 inch) length of air hose to the metal tube in the back
of the handpiece.
b) If you have a PACE system incorporating only one
handpiece, attach the air hose to the power cable using the
supplied Hose Clamps. Space them evenly along the length
of the power cable starting at a point 6 inches from the ends
of the handpiece.
c) If you have a PACE system incorporating 2 or more air
handpieces, you may wish to leave the air hose assembly
unattached to allow a quick change to any air handpiece
being used.
2. Prepare a VisiFilter in the following manner:
a) Connect a 1 inch (2.5cm) length of clear pvc air hose to the
FLOW OUT side of the VisiFilter; push and turn the hose
onto the VisiFilter nipple to seat.
b) Insert the ribbed end of a male quick connect hose mount fitting (P/N 1259-0087) into the
free end of the 1 inch (2.5cm) length of air hose connected to the FLOW OUT side of the
VisiFilter.
c) Connect the free end of the 137cm (54 inch) length of air hose to the FLOW IN side of
the VisiFilter.
d) Insert the end of the quick connect hose mount fitting (on VisiFilter FLOW OUT side) into
the power source Vacuum Port.
3. When using air pressure, and/or utilizing multiple air handpieces, PACE recommends the use of
the following set up procedure which utilizes additional quick connect hose mount fittings. An
assortment of quick connect air fittings are supplied with each additional air handpiece.
a) Disconnect the 137cm (54 inch) length of air hose from the FLOW IN side of the VisiFilter
assembly. Insert the ribbed end of a male quick connect hose mount fitting (P/N 1259-0087)
into the free end of this air hose.
b) Connect the free end of a 1 inch (2.5cm) length of air hose with an installed female quick
connect hose mount fitting (P/N 1259-0086) to the FLOW IN side of the VisiFilter Assembly.
c) The 137cm (54 inch) length of air hose can now be easily moved between the VisiFilter
Assembly and the Controllable Pressure Port. The VisiFilter assembly remains connected to
the Vacuum Port.
4. Additional fittings may also be added to the hose connection at the rear of each air handpiece
to ease changing of handpieces.
NOTE: When removing any air hose, turn and pull. Do not attempt to pull hose directly off.
Damage to or breakage of fitting or VisiFilter may occur. Use your Sodr-X-Tractor with
a clean VisiFilter element. Otherwise a deterioration in performance or damage to the
unit may occur.