Quick Start Procedure - Pace Sodrtek ST 145 Operation And Maintenance Manual

Desoldering system
Table of Contents

Advertisement

5. The display will read "brn" when the Program (
released.
6. Press the Scroll Up
begin to heat. The temperature of the heater will stabilize at 315°C (600 °F) for 10
minutes.
7. At the conclusion of the 10-minute period, the heater temperature will increase to
427°C (800°F) for 15 minutes.
8. At the conclusion of the 15-minute time period, the heater is turned off and the Display will
read "End". Press and release the Scroll Up Key
normal operation.
CAUTION: The heater will be hot at the conclusion of the Burn In procedure.
NOTE: The microprocessor circuitry within the unit monitors the system to ensure proper results.
If any abnormalities are encountered, the Burn In cycle will be interrupted and an error
message displayed. If this situation should occur, turn the system off and perform the
procedure again. If the cycle is interrupted a second time, refer to the Corrective
Maintenance section and check for handpiece malfunction information.
handpiece is available, perform the procedure using that handpiece.
This procedure should be performed whenever a new handpiece or new heater is
connected to the system. Ensure that the system is placed in a well-ventilated area.
Smoke will be generated during the burn in cycle and while soldering. Fume extraction
equipment is recommended.

Quick Start Procedure

The ST 145 system is very easy to operate. As received from the factory, the system can be quickly set
up for use in standard desoldering/soldering operations. Simply perform the following Quick Start
Procedure to begin system operation.
1. Ensure that the Set-Up procedure has been performed; including the Heater Burn In procedure.
Check for the following:
a) Handpiece connections (connector plug and air hose) to the power
source.
b) Proper tip installed in handpiece.
c) Power cord connection between house AC supply receptacle and
the power source.
d) House air supply connection to power supply.
2. Turn the Power Switch "On" ("I").
3. Press the Scroll Up
within 5 seconds, the system will revert to normal operation. Allow time for the system to change
back.
4. Press the Scroll Up
5. Adjust the Set Temperature in the following manner:
©2004 PACE Inc., Annapolis Junction, Maryland
All Rights Reserved
Key to initiate the Burn In Mode. The handpiece heater will
Key. The Set Temperature is now displayed. If no other Key is pressed
Key. The Set Temperature is now displayed; immediately perform step 5.
) and Scroll Up
keys are
to exit Heater Burn In and return the to
Page 11 of 22
If a second

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sodrtek st 145e

Table of Contents