production environment for monitoring of set temperatures, since under most production
circumstances the temperature will not deviate.
TEMPERATURE SETBACK - System feature which, when enabled, will independently set back the
Set Tip Temperature to 177°C (350°F) after a user selected period of handpiece inactivity (10 to 90
minutes, settable in 10 minute increments). This feature is enabled (or disabled) in the Set-Up Mode.
TIP OFFSET CONSTANT - Specific value for a given handpiece/tip combination upon which the
system automatically calculates the correct Tip Temperature Offset at any entered Set Tip
Temperature. This value is the temperature loss (Tip Temperature Offset) at 371°C (700°F) and is set
in the Set-Up Mode. A value of 0-115°C (0-240°F) may be entered in the Set-Up Mode.
TIP TEMPERATURE OFFSET - Difference in value between the temperature measured by the
temperature sensor (at the heater) and the true temperature of the tip at a given Set Tip Temperature.
Packing List
Item #
Description
1
System Power Supply
2
System Power Supply (Export)
5
Power Cord, 115V
6
Power Cord, 230V
7
Tip Tool
8
Hex Key, .050
9
Hot Grip Removal Pad
10
Operations Manual CD
Spare Parts
Item #
Description
1
Fuse, 1.25 Amp, 250 V, Time Lag (ST 145)
Fuse, 0.63 Amp, 250 V, Time Lag (ST 145E)
2
TEKLINK Cable
3
TEKLINK Remote Box
4
Tip & Temperature Selection Chart
Service
Please contact PACE or your local distributor for service and repair.
©2004 PACE Inc., Annapolis Junction, Maryland
All Rights Reserved
Part Number
ST 145
Only
1
0
1332-0094
1
1332-0093
0
1100-0206
0
1100-0237
1
1100-0307
0
CD5050-0459
1
ST 145 E
Only
0
1
0
1
0
1
0
1
PACE Part Number
1159-0251-P5
1159-0252-P5
1332-0252-P1
3008-0218-P1
5050-0251