General Information; Introduction; Specifications - Pace Sodrtek ST 145 Operation And Maintenance Manual

Desoldering system
Table of Contents

Advertisement

General Information

Introduction

Thank you for purchasing the PACE SODRTEK
manual will provide you with the information necessary to properly set up, operate and maintain the
ST 145.
The ST 145 system is available in either 115 VAC or 230 VAC versions, which incorporates a highly
responsive SensaTemp (closed loop) control system providing up to 80 Watts of total power to a
single output channel.
assures the user that it conforms to EMC 89/336/EEC.
The 115 VAC version systems conform to FCC Emission Control Standard, Title 47, Subpart B, Class
A. This standard is designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment.

Specifications

System Power Source Power Requirements
ST 145
ST 145E
Temperature Specifications
Handpieces Tip Temperature Range: 204 to 455°C (400 to 850°F) nominal.
Temperature Stability: ±1.1°C (±2°F) at idle from set tip temp.
NOTE:
Actual minimum and maximum Operating Tip Temperatures may vary depending on
Handpiece, Tip Selection and application.
Vacuum And Air
Measurements at front panel Vacuum and Controllable Pressure Ports.
Vacuum Rise Time: ------- 150 ms average.
Vacuum: ............................ 51 cm Hg. (20 in. Hg.) (nominal)
Pressure: .......................... 1.44 Bar (21 P.S.I.) (nominal at MAX setting)
Air Flow: ........................... 6 SLPM (0.22 SCFM) maximum
EOS/ESD Specifications
The specifications shown below apply except on "Soft Ground Systems" which have a 1meg
ohm current limiting resistance and a label placed on the power source front panel referring
to EN 100015-1.
Tip-To-Ground Resistance: Less than 2 ohms.
AC Leakage: Less than 2 Millivolts RMS from 50Hz to 10MHz.
Transient Level: Less than 500mV peak, out to 100MHz.
©2004 PACE Inc., Annapolis Junction, Maryland
All Rights Reserved
The 230 VAC version system bears the CE Conformity Marking, which
Operates on 97-127 VAC, 50/60Hz, 120 Watts maximum at
115 VAC, 60Hz
Operates on 197-253 VAC 50/60Hz, 120 Watts maximum at
230 VAC, 50Hz
®