  • Page 1 ► Assembly, installation and operating instructions Keep these instructions in a safe place for future use! Issue05/20EN SAP No.1371885...
  • Page 3: Table Of Contents

    Table of contents 1 General ..........................6 1.1 About these instructions ......................... 1.2 Explanation of Symbols........................... 2 Safety............................ 7 2.1 Correct use.............................. 2.2 Limits of operation and use ........................2.3 Risk from electrocution!.......................... 2.4 Personnel requirements - Qualifications ....................10 2.5 Personal Protective Equipment .......................
  • Page 4 7 Electrical wiring ........................29 7.1 Maximum electrical rating values ......................29 7.2 Electromechanical control type ...58/56/68..................... 31 7.2.1 Connection (**00) ............................ 31 7.2.2 Cabling TOP (**00), activation via speed controller type 30510............... 33 7.2.3 Cabling TOP (**00), activation via speed controller type 30510 with industrial thermostat type 30058/ 30059................................
  • Page 5 12 List of KaControl parameters....................62 12.1 TOP parameter list ..........................62 12.2 KaController parameter list........................65 13 Certificates..........................67 13.1 153_EU-Konformitätserklärung_Lufterhitzer ..................68 13.2 ERP Datenblatt TOP ..........................70 Table ............................. 72...
  • Page 6: General

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions General About these instructions These instructions ensure the safe and efficient handling of this equipment. These instructions form an integral part of the equipment and have to be kept in the direct vicinity of the equipment and available to personnel at all times. All personnel must have carefully read through these instructions prior to commencing all work on the equipment.
  • Page 7: Safety

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Safety This section provides an overview of all important safety aspects to ensure optimum protection of personnel as well as safe and trouble-free operation. In addition to the safety instructions in these operating instructions, the valid safety, accident pre- vention and environmental protection regulations must be observed for the area of use of the unit.
  • Page 8: Limits Of Operation And Use

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Limits of operation and use Limits of operation Min./max. water temperature °C 5 - siehe Typenschild Min./max. air intake temperature °C -20 - (+40) Min./max. air humidity 15-75 Min. operating pressure bar/kPa Max.
  • Page 9: Risk From Electrocution

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions WARNING! Respect the maximum flow temperatures to protect the EC fan! Prolonged downtimes can lead to impermissible heating of the EC fan motor if heating media temperatures are too high. The flow temperatures should therefore be limited depending on the application and the mo- tor model.
  • Page 10: Personnel Requirements - Qualifications

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Personnel requirements - Qualifications Specialist knowledge The installation of this product requires specialist knowledge of heating, cooling, ventilation, installation and electrical engin- eering. This knowledge, generally learned in vocational training in one of the fields mentioned above, is not described separ- ately.
  • Page 11: Transport, Storage And Packaging

    IMPORTANT NOTE! Warranty claims can only be made within the applicable period for complaints. (More information is avail- able in the T&Cs on the Kampmann website) IMPORTANT NOTE! 2 people are needed to transport the unit. Wear personal protective clothing when transporting the unit.
  • Page 12: Storage

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Storage Store packaging under the following conditions: Do not store outdoors. Store in a dry and dust-free place. Store in a frost-free place. Do not expose to aggressive media. Protect from direct sunlight. Avoid mechanical vibrations and shocks.
  • Page 13: Technical Data

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Technical data Unit Series Water content [l] 1.6 - 6.1 2.2 - 8.2 3.4 - 11.5 4.8 - 16.8 5.3 - 17.0 Weight [kg] 25 – 62 32 -92 45 – 125 53 –...
  • Page 14: Construction And Function

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Construction and function Overview Fig. 1: TOP at a glance Fan guard Whisper-quiet sickle-blade fan Rear panel with nozzle Heat exchanger (example - copper/aluminium model) Air heater housing Louvre, 1-row (standard) Brief description TOP unit heaters are used for the decentralised heating and ventilation of high-ceilinged buildings, either wall- or ceiling- mounted.
  • Page 15: Installation And Wiring

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Installation and wiring Requirements governing the installation site Only install and assemble the unit if the following conditions are met: Make sure that the wall/ceiling is sufficiently load-bearing to take the weight of the unit (Technical data [} 13]). Make sure that the unit is securely suspended/standing.
  • Page 16: Installation Of Sheet Steel Accessories

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Installation 2 people are needed to install the unit. CAUTION! Risk of injury from sharp metal housing! The inner metal of the casing can have sharp edges. Wear suitable protective gloves. IMPORTANT NOTE! Horizontal installation of units! When installing the units, ensure that they are completely horizontal to ensure proper operation.
  • Page 17 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Figure Description Dimensions [mm] Suitable for Series 44 Series 45 Series 46 Wide nozzle, type 3*007 Series 47 Series 44 Series 45 Series 46 Induction louvre, type 3*101 Series 47 RaDeck ceiling air outlet, type Series 44-47 3*087 KaMAX air outlet, type 3*111...
  • Page 18 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Figure Description Dimensions [mm] Suitable for Universal bracket extension, type All series 30043 Wall bracket, type 34044 Series 44 Wall bracket, type 35044 Series 45 Wall bracket, type 36044 Series 46 Wall bracket, type 37044 Series 47...
  • Page 19 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Figure Description Dimensions [mm] Suitable for Wall brackets, extended, type Series 44 30022 Wall brackets, extended, type Series 45 30024 Wall brackets, extended, type Series 46 30026 1080 Wall brackets, extended, type Series 47 30020 Dimensions depending on bracket length...
  • Page 20 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Figure Description Dimensions [mm] Suitable for Series 44 Series 45 Series 46 Filter box, filter ISO Coarse 90%. Type 3*010 Series 47 Sailcloth connection, type 3*013 Series 44-47 Series 44 Series 45 Series 46 Air duct 90°, type 3*021 Series 47...
  • Page 21 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Figure Description Dimensions [mm] Suitable for Variable Series 44 Variable Series 45 Variable Series 46 Air duct, type 3*015 Variable Series 47 Tab. 7: Air-side sheet steel accessories Fig. 3: Connecting frame dimensions Series A [mm] B [mm]...
  • Page 22: Suspension Points

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Factory-fitted accessories Description Add-on to unit heater type Frost protection thermostat ..F Repair switch ..R KaControl module, incl. repair switch .
  • Page 23: Universal 2-Point Brackets Type 30041

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 6.3.3 Universal 2-point brackets type 30041 Fig. 5: Universal 2-point brackets, series 44-47 6.3.4 Universal 2-point brackets type 38041 Fig. 6: Universal 2-point brackets, series 48...
  • Page 24: Universal 4-Point Brackets Type 30042

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 6.3.5 Universal 4-point brackets type 30042 Fig. 7: Universal 4-point brackets, series 44-47 6.3.6 Universal 4-point brackets type 38042 Fig. 8: Universal 4-point brackets, series 48...
  • Page 25: Universal 2-Point T-Brackets Type 30047

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 6.3.7 Universal 2-point T-brackets type 30047 Fig. 9: Universal 2-point T-brackets, series 44-47 6.3.8 Wall brackets, type 3*044, type 3002* Fig. 10: Wall brackets * Wall bracket, extended (type 3002*)
  • Page 26: Ceiling To Wall Brackets Type 3*049

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 6.3.9 Ceiling to wall brackets type 3*049 Fig. 11: Ceiling to wall bracket installation 6.3.10 Louvres Fig. 12: Louvres Induction louvre mounting (type 3*101): A + B Induction louvre mounting, 2-row (type 3*002): A + C + D...
  • Page 27: Installation

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Installation Hydraulic connection Note the following points when connecting the hydraulic side: Install and test safety components (expansion vessels, pressure relief valves and overflow valves). Route condensation lines with a sufficient cross-section without bends and narrow sections with a gradient to the waste water pipe on site.
  • Page 28: Connection To The Pipe Network

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 6.4.1 Connection to the pipe network The flow and return connections protrude laterally from the housing. The heat exchanger connection dimensions for copper/ aluminium, galvanised and cross-current heat exchangers are: 1" (series 44+45) 1 ¼"...
  • Page 29: Electrical Wiring

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Electrical wiring IMPORTANT NOTE! Switch the unit on and off at the control input! Do not switch the unit on and off at the mains, since a fault message is generated for up to 10 seconds after the mains power is switched on! After this time, the EC fan's electronic circuit is ready for operation and a reliable status message is possible.
  • Page 30: Maximum Electrical Rating Values

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Maximum electrical rating values Electromechanical model (type ... 58/56/68), KaControl model (type ...58C1/56C1/68C1) Type Rated Mains fre- Active Rated cur- Leakage cur- Maximum IP protec- Protection voltage [V] quency [Hz] power [kW] rent [A] rent [mA] pre-fusing...
  • Page 31: Electromechanical Control Type

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Electromechanical control type ...58/56/68 EMC-compliant installation of control cables To avoid interference, ensure there is sufficient clearance between the mains power and control cables. When using a shiel- ded cable, make sure that the shield is connected just on one side, i.e. only to the signal source with the protective earth (as short and low inductance as possible)! 7.2.1 Connection (**00) Voltage supply and activation...
  • Page 32 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Control via 0 - 10 VDC The 0 - 10 VDC control signal is interpreted for speed according to the following values: Control signal Function 2 - 10 V - 100% (2 V) The speed can be limited to approx.
  • Page 33: Cabling Top (**00), Activation Via Speed Controller Type 30510

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.2.2 Cabling TOP (**00), activation via speed controller type 30510...
  • Page 34: Cabling Top (**00), Activation Via Speed Controller Type 30510 With Industrial Thermostat Type 30058

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.2.3 Cabling TOP (**00), activation via speed controller type 30510 with industrial thermostat type 30058/ 30059 Heating...
  • Page 35: Cabling Top (**00), Activation Via Speed Controller Type 30510 With Room Thermostat Type 30055

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.2.4 Cabling TOP (**00), activation via speed controller type 30510 with room thermostat type 30055 Heating...
  • Page 36: Cabling Top (**00), Activation Via Speed Controller Type 30510 With Room Thermostat Type 30056

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.2.5 Cabling TOP (**00), activation via speed controller type 30510 with room thermostat type 30056 Heating...
  • Page 37: Cabling Top (**00), Activation Via Air Conditioning Controller Type 30155, 2-Wire Valve Actuator 230 V

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.2.6 Cabling TOP (**00), activation via air conditioning controller type 30155, 2-wire valve actuator 230 V AC, open/ closed...
  • Page 38: Cabling Top (**00), Activation Via Air Conditioning Controller Type 30256, 2-Wire Valve Actuator 230 V

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.2.7 Cabling TOP (**00), activation via air conditioning controller type 30256, 2-wire valve actuator 230 V AC, open/ closed...
  • Page 39: Cabling Top (*00), Activation Via Speed Controller Type 30515

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.2.8 Cabling TOP (*00), activation via speed controller type 30515...
  • Page 40: Cabling Top (**00), Activation Via Ddc/Bct, 2-Wire Valve Actuator 230 V Ac, Open/Closed

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.2.9 Cabling TOP (**00), activation via DDC/BCT, 2-wire valve actuator 230 V AC, open/closed 2-pipe heating/cooling 2-pipe heating/cooling Unit 2 motor fault Contact open = fault Unit 2 speed (respect unit’s internal resistance!) Unit 1 motor fault Contact open = fault Unit 1 speed...
  • Page 41: Kacontrol (*C1)

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions KaControl (*C1) 7.3.1 KaController installation Fig. 15: Installation of flush-mounted back box Electrical wiring Connect the KaController to the nearest KaControl unit in line with the wiring diagram. The maximum bus length between the KaController and the KaControl master unit is 30 m.
  • Page 42: Connection (*C1)

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.3.2 Connection (*C1) General information Route all low voltage cables along the shortest route. Ensure that low-voltage and power cables are separated, using metal partitions on cable harnesses. Wrong! Use only shielded cables as low-voltage and bus cables. Star-shaped wiring of the bus lines.
  • Page 43 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions IMPORTANT NOTE! Use shielded, paired cables as bus cables, UNITRONIC® BUS LD 2x2x0.22, but at least of the same value or higher. IMPORTANT NOTE! When laying bus cables, avoid the formation of star points, for instance in junction boxes. Loop the cables through to the units! Description of wiring Fig. 18: TOP with KaControl module...
  • Page 44 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions The type of activation is set by 6 DIP switches on the SmartBoard in accordance with the wiring diagram and system config- uration. Control via 0 - 10 VDC The 0-10 VDC control signal at input terminals AI2 and GND (Ri = 20 kOhm) on the SmartBoard is interpreted for speed and valve control according to the following values: Control signal Function...
  • Page 45 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Voltage supply and fusing EC fan and KaControl recirculation air module are supplied together with 230 V/50 Hz voltage via a supply line. An operating indicator LED is located on the terminal circuit board in the KaControl module. Also installed on the terminal circuit board is a unit fuse Ø5 x 20 mm on the primary side for the control voltage, as well as on the secondary side for the 24 V voltage and a unit fuse Ø5 x 20 mm on the SmartBoard.
  • Page 46 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Observe these points in the following installation diagrams for TOP with KaControl: Comply with the details on cable types and cabling with due consideration for VDE 0100. None *: NYM-J. The requisite number of wires, including protective earth, is stated on the cable. Cross-sections are not stated as the cable length is included in the calculation of the cross-section.
  • Page 47: Cabling Top (*C1), Activation Via Kacontroller Type 321000X, 2-Wire, Valve 24 Vdc, Open/Closed

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.3.3 Cabling TOP (*C1), activation via KaController type 321000x, 2-wire, valve 24 VDC, open/closed...
  • Page 48: Cabling Top (*C1), Activation Via Kacontroller Type 321000X, 2-Wire, Valve 24 Vdc, Open/Closed, With

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.3.4 Cabling TOP (*C1), activation via KaController type 321000x, 2-wire, valve 24 VDC, open/closed, with CAN bus card...
  • Page 49: Cabling Top (*C1), Activation Via In Situ 0-10 Vdc Signal

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 7.3.5 Cabling TOP (*C1), activation via in situ 0-10 VDC signal 2-pipe heating/cooling respect unit’s internal resistance!
  • Page 50: Pre-Commissioning Checks

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Pre-commissioning checks Check before initial commissioning whether all necessary conditions have been met so that the unit can function safely and properly. Structural tests Check that the unit is securely standing and fixed. Check that the unit is horizontal.
  • Page 51: Operation

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Operation Operation of electromechanical control Speed controller type 30510 The speed controller is used to activate the fan and pre-set the fan speed. Actu- ation of a thermoelectric shut-off valve is not possible. Fig. 20: Speed controller type 30510 Electronic speed controller, type 30515 With integrated digital timer, protection rating IP 40...
  • Page 52 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Clock thermostat 230 V, type 30256 Electronic clock thermostat for 2- and 4-pipe applications, surface-mounted wall installation on a flush-mounted box in visually unobtrusive design Operation using 4 sensor keys Timer with automatic summer/winter changeover Option for external room sensor Control input for heating/cooling changeover with 2-pipe applications Digital input can be set to Comfort/ECO or ON/OFF switchover...
  • Page 53: Operation Of The Kacontroller

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Operation of the KaController The following information is limited to the key content on the operation of the KaController and KaControl system. More in- formation is included separately in the KaControl SmartBoard user manual. 9.2.1 Function keys, display elements All menus can be selected and set using the navigator dial.
  • Page 54 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions KaController, black without function keys (one-button opera- tion) type 3210006 1. Display with LED background lighting 2. Navigator dial Change settings Call up menus Fig. 27: KaController black, type 3210006 The symbols shown on the display depend on the application (2-pipe, 4-pipe etc.) and the parameters set. Fig. 28: Display Display of setpoint room temperature Current time...
  • Page 55: Maintenance

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Maintenance 10.1 Securing against reconnection DANGER! Risk of death by unauthorised or uncontrolled restart! Unauthorised or uncontrolled restarting of the equipment can result in serious injury or death. Before restarting, ensure that all safety devices are fitted and working properly and that there is no haz- ard to humans.
  • Page 56: Clean The Inside Of The Unit

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 10.3 Clean the inside of the unit Check all elements that come into contact with air (internal surfaces of the unit, outlet elements etc.) for dirt or deposits dur- ing maintenance and use a commercially available product to remove. DANGER! Risk of injury from burning The electronics housing of the EC fan reaches high temperatures.
  • Page 57: Replacing The Filter

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 10.4 Replacing the filter. CAUTION! Risk of injury from sharp metal housing! The inner metal of the casing can have sharp edges. Wear suitable protective gloves. Fig. 29: Changing the ISO Coarse 90% filter cartridge...
  • Page 58: Faults

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Faults The following chapter describes possible causes of faults and the work needed to rectify them. Should faults occur frequently, shorten the maintenance intervals in line with the actual loading on the unit. Contact the manufacturer with any faults that cannot be rectified using the following information Behaviour in the event of faults The following applies:...
  • Page 59: Fault Table

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions LED code Relay in the fan* Cause Mains power too high Fault, peak current Temperature alarm MODBUS communication fault Tab. 13: Status via flash code * Relay in the fan with factory-programmed function (fault message not inverted) 0 relay de-energised 1 relay energised 11.1 Fault table...
  • Page 60: Fault Table, Electromechanical Control Type

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Fault Possible cause Remedy Air in the heat exchanger. Vent heat exchanger. Speed too high. Set a lower speed, if possible. Air inlet/outlet opening is obstructed. Free air ducts. Filter dirty. Replace filter.
  • Page 61: Kacontrol Faults

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions 11.4 KaControl faults Code Alarms Priority Faulty control sensor. Motor fault. Room frost protection. Condensation alarm. General alarm. Sensor AI1, AI2 or AI3 faulty. Unit frost protection. EEPROM error. Offline slave in the CAN bus network. Tab. 14: KaControl unit alarms Code Alarms...
  • Page 62: List Of Kacontrol Parameters

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions List of KaControl parameters 12.1 TOP parameter list Parameter Function Standard Min. Max. Unit P000 Software version P001 Base setpoint for setpoint input ± 3K °C P002 Switching on / off hysteresis for valves K/10 P003 Neutral zone in a 4-pipe system (only in automatic mode)
  • Page 63 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Parameter Function Standard Min. Max. Unit Fan run-on time after operating mode is switched to stage P035 P036 Type of setpoint P037 Display P038 Lock/disable function on control unit P039 Function of digital output V2 (in 2-pipe system) P040 Valve actuation via pulse width modulation Reset time of PI controller to activate the fan in automatic...
  • Page 64 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Parameter Function Standard Min. Max. Unit P075 Serial address of Slave 5 P076 Serial address of Slave 6 P077 Serial address of Slave 7 P078 Serial address of Slave 8 P079 Serial address of Slave 9 P080 Serial address of Slave 10...
  • Page 65: Kacontroller Parameter List

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Parameter Function Standard Min. Max. Unit P118 On delay time P119 Off delay time P120 reserved P121 reserved P122 Relative fan speed increase via contact P123 Maximum valve running time P124 Minimum P + I output variation for valve motion (0 to 10) P125 reserved...
  • Page 66 Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Para- Function Standard Min. Max. Unit Comment meter Interval of setpoint setting 0 = Automatic setting depending on t011 PCB (parameterisable, freely programmable) 1 = Increment of 1℃ (parametrisable PCBs) 2 = Increment of 0.5 ℃ (freely programmable PCBs) t012 Date/Time setting: Year t013...
  • Page 67: Certificates

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Certificates...
  • Page 70: Erp Datenblatt Top

    20 °C (Trockenkugel) Einlass 65 °C für 4-Rohrsysteme Wassertemperatur 10 °C für 4- Heizbetrieb Rohrsysteme Sound power test At ambient conditions without water flow Test Schallleistungspegel Bei Umgebungsbedingungen ohne Wasserdurchsatz Kampmann GmbH Contact Details Friedrich-Ebert-Straße 128-130, D-49811 Lingen (Ems), Germany Kontaktinformationen...
  • Page 71 20 °C (Trockenkugel) Einlass 65 °C für 4-Rohrsysteme Wassertemperatur 10 °C für 4- Heizbetrieb Rohrsysteme Sound power test At ambient conditions without water flow Test Schallleistungspegel Bei Umgebungsbedingungen ohne Wasserdurchsatz Kampmann GmbH Contact Details Friedrich-Ebert-Straße 128-130, D-49811 Lingen (Ems), Germany Kontaktinformationen...
  • Page 72: Table

    Lufterhitzer mit stufenlosem EC-Wechselstrommotor Assembly, installation and operating instructions Table Tab. 1 Limits of operation..............................8 Tab. 2 Maximum flow temperatures ..........................8 Tab. 3 Operating voltage..............................8 Tab. 4 Water quality ................................8 Tab. 5 Technical data, TOP ..............................13 Tab.