MTS Systems Temposonics T Series Operation Manual page 34

Magnetostrictive linear position sensors ssi atex / iecex / cec / nec / kcs / eac ex certified
Table of Contents

Advertisement

Temposonics
TH SSI ATEX / IECEx / CEC / NEC / KCs / EAC Ex certified / Japanese approval
®
Operation Manual
Electrical connection
Connection type
Operating voltage
Ripple
Current consumption
Dielectric strength
Polarity protection
Overvoltage protection
Certifications
Certifi cation required
Version E
IECEx / ATEX
Ex db eb IIC T4 Ga/Gb
(IECEx: Global market;
Ex tb IIIC T130°C Ga/Db
ATEX: Europe)
Zone 0/1, Zone 21
−40 °C ≤ Ta ≤ 75 °C
NEC
(USA)
CEC
(Canada)
EAC Ex
Ga/Gb Ex db eb IIC T4 X
(Russian market)
Da/Db Ex tb IIIC T130°C X
Zone 0/1, Zone 21
−40 °C ≤ Ta ≤ 75 °C
KCs
Ex d e IIC T4
(South Korea)
Ex tb IIIC T130°C
Zone 0/1; Zone 21
−40 °C ≤ Ta ≤ 75 °C
Japanese approval
Ex d e IIC T4 Ga/Gb
Ex t IIIC T130°C Db
Zone 0/1, Zone 21
−40 °C ≤ Ta ≤ 75 °C
Fig. 37: Certifications
T-Series terminal
+24 VDC (−15 / +20 %)
≤ 0.28 V
PP
100 mA typical
700 VDC (DC ground to machine ground)
Up to −30 VDC
Up to 36 VDC
Version D
Ex db IIC T4 Ga/Gb
Ex tb IIIC T130°C Ga/Db
Zone 0/1, Zone 21
−40 °C ≤ Ta ≤ 75 °C
Ga/Gb Ex db IIC T4 X
Da/Db Ex tb IIIC T130°C X
Zone 0/1, Zone 21
−40 °C ≤ Ta ≤ 75 °C
Ex d IIC T4
Ex tb IIIC T130°C
Zone 0/1; Zone 21
−40 °C ≤ Ta ≤ 75 °C
Ex d IIC T4 Ga/Gb
Ex t IIIC T130°C Db
Zone 0/1, Zone 21
−40 °C ≤ Ta ≤ 75 °C
34
Version G
Ex db IIC T4 Ga/Gb
Ex tb IIIC T130°C Ga/Db
Zone 0/1, Zone 21
−40 °C ≤ Ta ≤ 75 °C
Explosionproof
Class I Div. 1
Groups A, B, C, D T4
Class II/III Div. 1
Groups E, F, G T130°C
−40 °C ≤ Ta ≤ 75 °C
Flameproof
Class I Zone 0/1 AEx d IIC T4
Class II/III Zone 21 AEx tb IIIC T130°C
−40 °C ≤ Ta ≤ 75 °C
Explosionproof
Class I Div. 1
Groups B, C, D T4
Class II/III Div. 1
Groups E, F, G T130°C
−40 °C ≤ Ta ≤ 75 °C
Flameproof
Class I Zone 0/1 Ex d IIC T4 Ga/Gb
Class II/III Zone 21 Ex tb IIIC T130°C Db
−40 °C ≤ Ta ≤ 75 °C
Ga/Gb Ex db IIC T4 X
Da/Db Ex tb IIIC T130°C X
Zone 0/1, Zone 21
−40 °C ≤ Ta ≤ 75 °C
Ex d IIC T4
Ex tb IIIC T130°C
Zone 0/1; Zone 21
−40 °C ≤ Ta ≤ 75 °C
Ex d IIC T4 Ga/Gb
Ex t IIIC T130°C Db
Zone 0/1, Zone 21
−40 °C ≤ Ta ≤ 75 °C
Version N
No hazardous
area approval
No hazardous
area approval
No hazardous
area approval
No hazardous
area approval
No hazardous
area approval
No hazardous
area approval

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Temposonics th

Table of Contents