Detailed Specifications; Ac Voltage - Fluke 87V MAX User Manual

Hide thumbs Also See for 87V MAX:
Table of Contents

Advertisement

Detailed Specifications

For all detailed specifications:
Accuracy is specified for 2 years after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %.
Accuracy specifications take the form of ±([% of Reading] + [Number of least-significant digits]). For the 4 ½-digit mode, multiply the number
of least-significant digits (counts) by 10.

AC Voltage

AC conversions are ac-coupled and valid from 3 % to 100 % of range.
Range
Resolution
600.0 mV
0.1 mV
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
Low-Pass Filter
[1] Below 30 Hz, use smoothing function. Below 20 Hz add 0.6 %.
[2] Below 10 % of range, add 12 counts.
[3] Frequency range: 1 to 2.5 kHz
[4] Specification increases from -1 % to -6 % at 440 Hz when filter is used.
info@Fluke-Direct.ca
45 – 65 Hz
15 – 200 Hz
±(0.7 % + 4)
±(0.7 % + 2)
[1]
±(1.0 % + 4)
Fluke-Direct
Accuracy
200 – 440 Hz
440 Hz – 1 kHz
[1]
±(1.0 % + 4)
+1.0 % + 4
Unspecified
[4]
-6.0 % - 4
Digital Multimeter
Detailed Specifications
1 – 5 kHz
5 – 20 kHz
±(2 % + 4)
±(2 % + 20)
Unspecified
[3]
±(2 % + 4)
Unspecified
Unspecified
Unspecified
Unspecified
Unspecified