To prevent possible electric shock or
personal injury, do not use the low-pass filter
to verify the presence of hazardous voltages.
Voltages greater than what is indicated may
be present. First, make a voltage
measurement without the filter to detect the
possible presence of hazardous voltage.
Then, select the filter.
When the low-pass filter is selected, the Meter
goes to manual ranging mode. Select ranges by
pressing . Autoranging is not available with
the low-pass filter.
1 kHz
100 Hz

Temperature Measurements

The Meter measures the temperature of a type-K
thermocouple (included). Choose between degrees
Celsius (°C) or degrees Fahrenheit (°F) by pushing
.
info@Fluke-Direct.ca
XW Warning
Note
Figure 3. Low-Pass Filter
Fluke-Direct
To prevent possible damage to the Meter or
other equipment, remember that while the
Meter is rated for -200.0 °C to +1090.0 °C and
-328.0 °F to 1994 °F, the included type-K
thermocouple is rated to 260 °C. For
temperatures out of that range, use a higher
rated thermocouple.
Display ranges are -200.0 °C to +1090 °C and -328.0 °F
to 1994 °F. Readings outside of these ranges show  on
the Meter display. When there is no thermocouple
connected, the display also reads .
To measure temperature, do the following:
1.
Connect a type-K thermocouple to the Meter's COM
and  terminals.
2.
Turn the rotary switch to .
3.
Push  to enter temperature mode.
4.
Push  to choose Celsius or Fahrenheit.
aom11f.emf
Digital Multimeter
How to Make Measurements
W Caution
.ca
1.800.561.8187
13