Spare Drive Power Board Instructions
This document describes how to remove and replace a Drive
Power Board in a NEOxl 40 (3U) tape library module from
Overland Storage.
WARNING:
To reduce the risk of electric shock or damage to
equipment, always remove any power cords while working with
the library.
WARNUNG:
Um das Risiko eines elektrischen Schlags oder
Schäden am Gerät zu vermeiden, ziehen Sie stets den
Netzstecker, bevor Sie an der Einheit arbeiten.
AVERTISSEMENT:
Pour réduire le risque de choc électrique
ou endommagement de l'équipement, retirez toujours les
cordons électriques en travaillant avec l'appareil.
CAUTION:
While working with the library, observe standard
Electrostatic Discharge (ESD) precautions to prevent damage
to micro-circuitry or static-sensitive devices.

Identify the Failed Component Module

1. Using the RMI, from the Maintenance > UID LED Control
page, activate the Unit Identification (UID) LEDs to locate
the library in the data center containing the failed
component.
This will illuminate the blue LED on both the front and
rear of the Base Module to identify the library containing
the failed component.
2. To identify the module within the library that contains the
failed component, in the upper left corner of the Home
screen, locate the module that indicates an error.

Power Off Library

If still running, power off the library from the Base Module
front panel by pressing and holding down the power button for
three (3) seconds.
NOTE: If the library does not perform a soft shutdown, press and
hold the power button for 10 seconds.
Verify that the Robotic Assembly is in its parked position and
that all host processes are idle.
10400857-001
©2018 Overland Storage, Inc.
NEOxl
40 Tape Library
®
Page 1 of 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NEOxl 40 and is the answer not in the manual?

Questions and answers

Summary of Contents for Overland Tandberg NEOxl 40

  • Page 1 ® Spare Drive Power Board Instructions This document describes how to remove and replace a Drive Power Board in a NEOxl 40 (3U) tape library module from Overland Storage. WARNING: To reduce the risk of electric shock or damage to equipment, always remove any power cords while working with the library.
  • Page 2 NEO Spare Drive Power Board Instructions Prepare to Remove Controller Disconnect power cords and controller cables, noting where they connect. 1. If present, unplug any AC power cords (1). 2. Remove the expansion interconnect cables (2) from the module and any modules to which it is connected. NOTE: Completely removing the expansion interconnect cables from the modules prevents damaging the cables during module removal and replacement.
  • Page 3 NEO Spare Drive Power Board Instructions Verifying the Installation and Configuration Power on the library and check the following: • Verify that the library powers on and initializes correctly, and that the status is Ready. • Check that the event that indicated the Drive Power Board was faulty is cleared.

Table of Contents