Lincoln Electric Vantage 549X Manual page 9

Table of Contents

Advertisement

®
VANTAGE
549X
GENERAL DESCRIPTION
®
The Vantage
549X is a diesel engine-driven welding power
source. The machine uses a brush type alternating current
generator for DC multi-purpose welding, for 120/240 VAC single
phase and 240 VAC three phase auxiliary standby power. The
welding control system uses state of the art Chopper
®
Technology
.
The machine has been equipped with CrossLinc
provide weld cable communication for voltage control at the arc
without the need for a control cable.
TECHNICAL SPECIFICATIONS
INPUT - DIESEL ENGINE
Make /Model
(K3534-2, K3534-12)
®
Deutz
TD2.9L4
EPA Tier 4 Final Compliant
Speed (RPM)
High Idle 1800
Low Idle 1525
Full Load
Starting System
12 VDC Battery and Starter
with Automatic Glow Plugs
Battery Size
BCI Group Size 34
800 Cold Crank Amps
RATED OUTPUT @ 104°F(40°C) - WELDER
Duty Cycle
Welding Output
525 Amps
100%
(DC multi-purpose)
575 Amps
60%
(DC multi-purpose)
IEC 60974-1; IP23 Rated
®
Technology to
Description
4 Cylinder 49.4 HP (37 kW)
Turbocharged Water Cooled
Diesel Engine
Displacement
178 cu. in. (2.9L)
Bore x Stroke
3.62" x 4.33"
92mm x 110mm
Capacities
Fuel: 25 US gal. (94.6L)
Oil: 2.25 US gal. (8.5L)
Cooling System: 2.5 US gal.
(9.5L)
Volts at Rated Amps
41 Volts
38 Volts
OUTPUT @ 104°F(40°C) - WELD ER AND GENERATOR
Welding Mode
CC-Stick
Downhill Pipe (CC)
Touch Start TIG
CV-Wire
Arc Gouging
Open Circuit Voltage
60 Max OCV @ 1800 RPM
Auxiliary Power
120/240 VAC
11,000 Watts, 60 Hz., Single Phase
19,000 Watts, 60 Hz., Three Phase
RECEPTACLES
Receptacle
120 VAC Duplex (5-20R) GFCI Protected
240 VAC Three Phase (15-50R)
120/240 VAC Single Phase (14-50R)
PHYSICAL DIMENSIONS
Height
(2)
Width
(3)
Depth
Weight
(4)
(1) Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When weld-
ing, available auxiliary power will be reduced.
(2) Top of Enclosure. Add 16.1" (409 mm) for exhaust and air cleaner.
(3) Includes Door. Base is 31.6" (803 mm) wide.
(4) Approximate weight less fuel.
A-1
INSTALLATION
Output Range
30-575 Amps
40-350 Amps
20-350 Amps
10-45 Volts
60-575 Amps
(1)
Circuit Breaker
20 Amps
50 Amps
50 Amps
42.0 in. (1066.8 mm)
32.9 in. (835.7 mm)
69.0 in. (1753 mm)
1662 lbs. (753 kg)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents