Lincoln Electric Vantage 549X Manual page 19

Table of Contents

Advertisement

®
VANTAGE
549X
ACCESSORY CONNECTION DIAGRAMS
WARNING
Shut off welder before making or removing any electrical
connections.
When connecting an accessory to the Vantage
following steps should be taken:
• Shut off the welder.
• Connect your leads for the desired accessory. For electrode
positive, connect the electrode cable to the "+" terminal of
the welder and work cable to the "-" terminal of the welder.
42V / 120V Wire Feeder
Voltage Switch
Weld Mode
Selector
Switch
ACCESSORY
CrossLinc Feeder
CrossLinc Remote
Across The Arc Feeder
(Non CrossLinc)
42VAC Bench Feeder
w/Voltage Control
(Flex Feeds, LN-25 Dual)
42VAC Bench Feeder
w/o Voltage Control
(LF Feeders)
Submerged Arc Controllers
(NA-3, LT-7)
ArcLink Feeders
(Power Feed)
TIG Module
Spool Gun Module
®
549X, the
FIGURE A.6
Weld Terminals
Switch
TABLE A.4
WELD MODE
WELD TERMINALS
SWITCH
SWITCH
CV
Stick, Tig, Gouging
CV
CV
REMOTE
CV
REMOTE
CV/CC
REMOTE
ArcLink
TIG
REMOTE
CV
A-11
For electrode negative, connect the electrode cable "-"
terminal of the welder and work cable to the "+" terminal of
the welder. Installation diagrams for common setups are
included on the following pages.
• Set the WIRE FEEDER VOLTMETER switch to either "+" or "-"
as required by the electrode type (See Figure A.6).
• The switch positions on the Vantage
on the type of accessory chosen. Reference Table A.4 and
Figure A.6 for guidance on how to properly set up each
accessory.
Local/Remote Switch
LOCAL/REMOTE
SWITCH
ON
REMOTE
ON
REMOTE
ON
LOCAL
REMOTE
REMOTE
REMOTE
N/A
N/A
REMOTE
ON
LOCAL
INSTALLATION
®
549X will be dependent
Wire Feeder Voltmeter
Polarity Switch
115/42VAC
SWITCH
N/A
N/A
N/A
42VAC
42VAC
115VAC
N/A
N/A
N/A

Hide quick links: