Download Print this page

Installation - Seitron T.HYGROS THW02B Manual

Battery powered weekly digital programmable thermo-hygrostat

Advertisement

INSTALLATION

WARNING
- To adjust properly room temperature, install the thermostat
far from heat sources, airstreams or particularly cold walls
(thermal bridges).
- In order to grant the electrical safety, it is mandatory to
screw the programmable thermo-hygrostat body to the wall
mount plate through the two screws supplied which must be
mounted in the battery holder.
- If the load controlled by the relay of the programmable
thermo-hygrostat operates with mains voltage, the
connection must be made via an omnipolar switch complying
with current standards and with a contact opening of at least
3 mm in each pole.
- Installation and electrical wirings of this appliance must be
made by qualified technicians and in compliance with the
current standards.
- Before wiring the appliance be sure to turn the mains power off.
The device is designed to be installed in a standard recess (or wall)
mounted junction box with two or three modules or else directly on
the wall using the screw anchors provided.
To install the device carry out the following steps:
Release the wall mount plate fitted under the base of the
1
programmable thermo-hygrostat as shown in Fig. 2.
Fig. 2
Fix the plate directly on the wall or onto 2 or 3 module junction
2
boxes by means of the two holes for screws (distance between
centres: 60 mm or 85mm), taking care to pass the wires
through the opening as shown in Fig. 3.
Fig. 3
QUICK GUIDE FOR SETTING THE TIME SCHEDULE
• Press button ' P '.
• The display shows ' PrOG ' with the icon '
• Press key ' OK ': the display shows the word ' dAY ', the icon
'
' and the squares corresponding to the flashing days.
P
• Press buttons '
' and '
' in order to choose one of the four
days combinations available as pre-set.
• Press button ' OK ' to confirm the choice.
• The display shows hour 00:00 with the relevant dash, in the upside
right, flashing.
• Press one of the following buttons to select the temperature
regulation level desired:
Comfort mode:
Press the '
Off / Antifreeze:
Press the '
Economy mode:
Press the ' ' button.
Moving the time cursor: Press button '
Each time the button which sets the regulation mode is depressed,
the time cursor automatically jumps into the next half hour.
• Once the time schedule for the day or group of days selected has
been set, press button ' OK '.
The display will show the time schedule for the next day or group
of days until the whole week has been covered.
• Once the time schedule for the whole week has been set, press
button ' OK '. The programmable thermo-hygrostat will store the
program into its memory and the word ' MEMO ' is shown on the
display, then it will automatically quit the time schedule setting
procedure.
THW02B0000SE 027077 070616
Make electrical wirings by passing the wires through the
3
rectangular opening in the wall plate (Fig. 3), and according to
the diagram in Fig. 4 or Fig. 5.
Fig. 4
2
Fig. 5
Connect the remote sensor (if present) or the phone interface
1
to connector 'C' shown in Fig. 6. The load for the thermostat
section must be wired to the terminal block 'A' shown in Fig. 6,
meanwhile the load for the hygrostat section must be wired to
the terminal block 'B' shown in Fig. 6.
' turned on.
P
' button.
' button.
' or '
'.
B
A
C
5
Move the thermostat to the wall plate by fitting first the teeth
4
of the base with the relevant holes of the plate and then exert
a pressure on the device to the left side until the plastic teeth
of the plate snap.
1
Fig. 7
Secure the bodyof the programmable thermostat to the wall
5
plate using the supplied screw that is located inside the battery
compartment (Fig.8).
Fig. 8
Insert the batteries in the battery compartment (I in Fig. 1);
6
see paragraph ' HOW TO INSERT/REPLACE THE BATTERIES '.
Fig. 6
- ENGLISH -

Advertisement