Group
Value
F700
F701
F702
F703
F704
F705
F706
F707
F708
F709
F710
F711
F712
F713
F714
F715
F716
F717
F718
ACM (Appliance Communication Module) Energy Management Accessory
Interaction Fault Codes
Displayed
0 7 0 0
Stuck keys On ICID/ACM/ (Dispenser Boards)
0 7 0 1
Stuck Keys on Internal Temp Board
0 7 0 2
Stuck Keys on Deli Pan
0 7 0 3
Key inputs on Deli Pan Temp Board and Door Closed
0 7 0 4
Key Inputs on Deli Pan/FP Board and Door Closed
0 7 0 5
Auto fill Communication Error
0 7 0 6
Auto fill wrong version
0 7 0 7
ACM/Comm Communication Error
0 7 0 8
COM Wrong Version
0 7 0 9
Cold Water Cup Switch Input missing and 0x70 message
is received from COM (ACM Only)
0 7 1 0
Cold Water Cup Switch Input present and no dispense
message is received from COM (ACM Only)
0 7 1 1
Hot Water Cup Switch Input missing and dispense
message is received that requires the cup switch (ACM
Only)
0 7 1 2
Hot Water Cup Switch Input present and no dispense
message is received (ACM Only)
0 7 1 3
FF Door open for 15 minutes without closing
0 7 1 4
FF Door open for 60 min. in the last 24 hours
0 7 1 5
50 FF Door Openings in the last 24 hours.
0 7 1 6
FZ Door open for 15 minutes without closing
0 7 1 7
FZ Door open for 60 min. in the last 24 hrs.
0 7 1 8
50 FZ Door Openings in the last 24 hours.
Failure Code Definition
Setting Criteria
Stuck Key is present on ICID/ACM. Only send
once per each stuck key.
Stuck Key is present on Internal Temp. Only
send once per each stuck key.
Stuck Key is present on Deli Pan. Only send
once per each stuck key
FF Door is closed and a Key Input is detected
FF Door is closed and a key input is detected
AutoFill Module not communicating properly
The Version of the Auto fill module is not
compatible with the ACM Version
COM Module not communicating properly
COM Version is not compatible with the ACM
Dispense message is received and 30
seconds later the Cup Switch input is still not
present
Cup Switch input is present for 30 seconds
and no dispense message has been received
Dispense message is received and 30
seconds later the Cup Switch input is still not
present
Cup Switch input is present for 30 seconds
and no dispense message has been received
Usage or door switch
Usage or door switch
Usage or door switch
Usage or door switch
Usage or door switch
Usage or door switch
80