Group
Value
F500
F501
F502
F503
F504
F505
F506
F507
F508
F509
F510
F511
F512
F513
F514
F515 -
F599
Door Board Failure Codes
Displayed
Failure Code Definition
0 5 0 0
Can't reach Target Hot Water Temp.
0 5 0 1
Flow meter Missing.
0 5 0 2
Flow meter pulsing with no water dispensing.
0 5 0 3
Ice/water stops dispensing based on time (7 Minute
Timeout).
0 5 0 4
Can't Fill Hot water Tank
0 5 0 5
Overcurrent Flag1 Tripped
0 5 0 6
Overcurrent Flag2 Tripped
0 5 0 7
Cold Water Cup Switch Input missing
0 5 0 8
Cold Water Cup Switch Input present
0 5 0 9
Hot Water Cup Switch Input missing
0 5 1 0
Hot Water Cup Switch Input present
0 5 1 1
Door board Ice Mold Temp Invalid.
0 5 1 2
Door board Ice Box Invalid.
0 5 1 3
Door board HotWater1 Thermistor Invalid.
0 5 1 4
Door board HotWater2 Thermistor Invalid.
0 5 1 6 – 0 5 9 9
Door Board for Future Expansion.
Setting Criteria
Hot Water time limit expires and temperature not
reached.
No pulses/flow meter signal during Dispense.
Wait 1 minute after a dispense is over before running
this diagnostic
If the Dispense stops due to timeout
Hot water fill time expires without tripping the level
sensor.
Ice Box Gasket Heater
Recess, Mullion or Fill Tube Heater
Cup Switch message is received and 30 seconds
later the Cup Switch input is still not present
Cup Switch input is present for 30 seconds and no
Cup Switch message has been received
Hot Water message is received and 30 seconds later
the Cup Switch input is still not present
Cup Switch input is present for 30 seconds and no
Cup Switch message has been received
Thermistor temps do not match
78

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cye23tsPye23psPye23ks

Table of Contents