Property Values Supported By The Epv Sentence - ACR Electronics AISLink CA2 Installation Manual

Ais class a transceiver
Hide thumbs Also See for AISLink CA2:
Table of Contents

Advertisement

5.4 Property Values supported by the EPV sentence

Property
Description
Number
101
Sensor 1 Baud Rate
102
Sensor 1 Baud Rate
103
Sensor 1 Baud Rate
104
Long Range Port Baud Rate
105
DGNSS Port Baud Rate
106
Set the MMSI Number
107
Set the IMO Number
108
Long Range communications
interface
109
Long Range Broadcast
Channel 1
110
Long Range Broadcast
Channel 2
111
Change Admin Password
112
Change User Password
113
Locating Device Test Mode
114
AIS Silent Mode
115
Activation of location de-
vices
116
Sensor Alert Configuration
117
Pilot Port Access Mode
150-151
Extended Dimension EA
152-153
Extended Dimension EA
42
CA2 Installation Manual
Auth.
Req.
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
Yes
No
No
Y1-03-0294 Rev. A
Accepted Values
4800,9600,38400
4800,9600,38400
4800,9600,38400
4800,9600,38400
4800,9600,38400
All Valid
0000000-9999999
'A' = Automatic
'M' = Manual
As per ITU-R M.1084-
5
As per ITU-R M.1084-
5
Any Alphanumeric
value up to 30 letters
Any Alphanumeric
value up to 30 letters
0 = Normal Mode
1 = Display and out-
put locating devices in
test mode
0 = Normal Mode
1 = Receive Only
0 = No alert from
location devices
1 = Alerts from loca-
tion devices
Bit Fields:
Bit 2 – External EPFS
Bit 1 – Heading
Bit 0 – Rate of turn
0 = Normal Access
1 = Restricted Access
0 – 511
0-63
Default
Value
4800
4800
4800
38400
38400
000000000
0000000
A
1075
1075
1111
2222
0
0
1
7 (all on)
0
0
0
28/04/2020

Advertisement

Table of Contents
loading

Table of Contents