ACR Electronics AISLink CA2 Installation Manual page 16

Ais class a transceiver
Hide thumbs Also See for AISLink CA2:
Table of Contents

Advertisement

2.3.7 Data Termination Switches
DIP switches select a 120Ohm termination to the serial ports. If a port requires termination
push the appropriate switch to the ON position.
2.3.8 Pilot Plug Connector
On the front panel (under a rubber cover) there is a standard "Pilot Plug" connection.
The connector is suitable for an AMP/Receptacle, shell size 11, 9-pin plug.
2.3.9 USB Socket
The front panel Micro USB socket can be used for:
Data logging (insert a USB stick using the supplied USB on-the-go cable
(see section 1.4 item 12 in CA2 Box Content)
Data input / output
Firmware updates (see section 8.3 on page 46 of this manual)
ENSURE any equipment connected to this port is isolated from any exter-
!
nal earth connections
2.3.10 Cable Sizes and Specifications
Data cables should be suitable for the vessel on which the AIS Transceiver is being in-
stalled taking note of any restricted areas that may have specific cable requirements. Each
port has a +ve, -ve and ground connection which should all be connected to ensure there
is no interference cause by external influence.
Do not connect the shield of both the external equipment and the junction
!
box. Connect at one end only.
16
CA2 Installation Manual
Y1-03-0294 Rev. A
28/04/2020

Advertisement

Table of Contents
loading

Table of Contents