P-Adjusting The Door Perimeter Heaters; Q-Adjusting The Room Temperature Offset - Traulsen R & A Series Owner's Manual

Reach-in & roll-in refrigerators; pass-thru & roll-thru refrigerators; reach-in & roll-in freezers; reach-in refrigerator/freezers; reach-in & roll-in hot food cabinets; pass-thru & roll-thru hot food cabinets
Hide thumbs Also See for R & A Series:
Table of Contents

Advertisement

VII. INTELA-TRAUL
(continued)
®
VII. p - ADJUSTING THE DOOR PERIMETER HEATERS:
This parameter allows the customer to turn ON and OFF the anti-condensate door perimeter heaters.
This parameter is set to the highest setting (100) at the factory so that the door heaters stay on continu-
ously. If you choose to have the door heaters cycle on and off, lower this parameter to approximately 30.
If condensation forms around the doors, increase the parameter until condensation stops. The exact
setting will vary depending on ambient conditions. This feature is not available on undercounter mod-
els.
Follow the instructions to enter the customer access code on page 11. When the control displays
Thermostat Set High, press the down arrow key
until the control display reads
DewPoint Compensation Factor. Press the set button
. Press the arrow keys
to
SET
adjust the factor to your desired setting. When the display shows the factor you want press the set
button
. The display will then read
Thermostat Set Point High. You can use the up or
SET
down arrow keys
to scroll to the next parameter or press the alarm cancel button to exit
)
)
.
)
VII. q - ADJUSTING THE ROOM TEMPERATURE OFFSET:
The room temperature offset parameter allows a service technician or end user the ability to have the
display show a temperature that is within three degrees of the actual temperature being read by the
cabinet air sensor. This allows for continuity of reading between different temperature reading devices.
(i.e.: thermistor Vs thermocouple Vs handheld thermometer) This parameter is preset at the factory to
"0" or no offset.
Follow the instructions to enter the customer access code on page 11. When the control displays
Thermostat Set High, press the down arrow key
until the control display reads
Room Temperature Offset. Press the set button
.
Use the arrow keys
to adjust the
SET
offset to your desired setting. When the display shows the offset you want press the set button
.
SET
The display will then read
Thermostat Set Point High. You can use the up or down arrow
keys
to scroll to the next parameter or press the alarm cancel button to exit
.
)
)
)
-18-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents