Toro Spray Master Series Operator's Manual page 9

46in and 52in sprayer
Table of Contents

Advertisement

1. Spray pressure—Decrease
2. Spray pressure—Increase
3. Left nozzle spray—Off
4. Left nozzle spray—On
CAPACITY
Drop
ONE
Size
NOZZLE
IN GPM
PSI
30
VC
0.13
40
VC
0.15
142-3306
50
VC
0.17
60
C
0.18
30
VC
0.17
40
VC
0.20
142-3307
50
VC
0.22
60
VC
0.24
30
VC
0.22
40
VC
0.25
142-3308
50
VC
0.28
60
VC
0.31
30
XC
0.26
142-3309
40
VC
0.30
50
VC
0.34
30
XC
0.35
142-3310
40
XC
0.40
50
VC
0.45
30
XC
0.43
142-3311
40
XC
0.50
50
VC
0.56
30
XC
0.52
142-3312
40
XC
0.60
50
VC
0.67
*Grey tips are to be used ONLY the 4 tip booms*
HIGH VOLUME SPRAY CHART (XRC TIPS)
CAPACITY
Drop
ONE NOZZLE
Size
IN GPM
At 15 PSI
At 60 PSI
(1 bar)
(4 bar)
PSI
Pressure
Pressure
15
VC
0.61
20
VC
0.71
135-8413
30
C
0.87
40
C
1.00
15
XC
0.92
20
XC
1.06
117-5839
30
VC
1.30
40
C
1.50
*NOTE: Always double check your application rates.
Tabulations are based on spraying water at 70 ∞ F (21∞ C)
CAPACITY
_______SPACING ________
ONE
/\
20"
/\
NOZZLE
GPA
GALLONS PER 1,000 SQ. FT.
IN
4 MPH
5 MPH
3 MPH
4 MPH
OZ./MIN
17
9.7
7.7
0.29
0.22
19
11.1
8.9
0.34
0.26
22
12.6
10.1
0.39
0.29
23
13.4
10.7
0.41
0.31
22
12.6
10.1
0.39
0.29
26
14.9
11.9
0.45
0.34
28
16.3
13.1
0.50
0.37
31
17.8
14.3
0.54
0.41
28
16.3
13.1
0.50
0.37
32
18.6
14.9
0.57
0.43
36
21
16.6
0.63
0.48
40
23
18.4
0.70
0.53
33
19.3
15.4
0.59
0.44
38
22
17.8
0.68
0.51
44
25
20
0.77
0.58
45
26
21
0.79
0.60
51
30
24
0.91
0.68
58
33
27
1.00
0.77
55
32
26
0.97
0.73
64
37
30
1.10
0.85
72
42
33
1.30
0.95
67
39
31
1.20
0.88
77
45
36
1.40
1.00
86
50
40
1.50
1.10
__HIGH VOLUME SPRAYING (SPACING)_
CAPACITY
/\
20"
/\
ONE NOZZLE
GPA
GALLONS PER 1,000 SQ. FT.
IN OZ./MIN
4 MPH
5 MPH
3 MPH
4 MPH
78
45
36
1.40
1.00
91
53
42
1.60
1.20
111
65
52
2.00
1.50
128
74
59
2.30
1.70
118
68
55
2.10
1.60
136
79
63
2.40
1.80
166
97
77
2.90
2.20
192
111
89
3.40
2.60
Coarse
Very Coarse
Extremely Coarse
142-4366
5. Center nozzle spray—Off
6. Center nozzle spray—On
7. Right nozzle spray—Off
8. Right nozzle spray—On
Spreader / Sprayer Calibration:
Mixing of liquid or dry product should be in accordance to manufacturers labels. Remember this is designed
for low volume spraying so the mix will be more concentrated.
Remember that your machine is factory set to put down 1/3 gallon of liquid per 1,000 sq. ft ( at 5MPH and
40PSI ). For instance, some products call for 1.1 to 1.5 oz per 1,000 sq. ft. We would recommend using 1.3
(median value of 1.1 to 1.5). Since you are using a 1/3 gallon tip, you need to multiply by 3, then multiply that
5 MPH
amount by the number of gallons put in the tank.
0.18
0.20
1.3 (median value of 1.1 to 1.5) X 3 (1.3 gallon tip) X gallons of water needed. If you were filling a 30 gallon tank your
0.23
equation would look like this:
1.3 X 3 X 30 = 117 ounces in 30 gallons of water.
0.24
0.23
0.27
Approximate Granular Calibration
0.30
0.33
Lbs. per
Full Rate
Product
1,000 sq ft
0.30
1
0.34
0.38
Fine Pellets
2
0.42
3
2
0.35
4
0.41
Mixed Fine Pellets
0.46
6
2
0.48
0.54
Small Pellets
4
0.61
6
0.58
1
Nitrogen Pellets Med.
0.68
2
0.76
3
0.71
2
Med. Pellets & Granules
0.82
4
0.91
6
2
Large Heavy Pellets
4
6
*Calibrated at 5 MPH
Accuway
_
Accuway balances the spread pattern, by shifting the product placement on the spinner. Placing the product on the
impeller close to the shaft or the center will cause the spread pattern to be heavier to the right as it rides the impeller
for a longer period. If the product is placed on the outer edge of the impeller, the spread pattern will be heavier to the
left ( because the spinner is turning clockwise ).
5 MPH
0.83
1) Start with the Accuway control cable all the way forward or in ( this is home base ).
0.97
2) Begin to spread the product. As you are spreading you should be able to see the spread pattern in front of you.
1.20
Generally, all spreaders will tend to throw fertilizer heavy to the right. As you continue to spread, pull the Accuway
1.40
control towards you very slowly ( small increments ) until you begin to bring the spread pattern directly centered
1.30
in front of you.
3) Once you have the spread pattern centered, lock the Accuway cable in place. There should be no reason to reset
1.40
1.80
the Accuway for that product unless you see that the spread pattern has changed due to bumping the lever. If it has
2.00
changed slightly, simply re-adjust the pattern while you're spreading.
Fine
142-4373
9
Throw fertilizer back to the center of tire tracks
4.75
5.25
5.5
5.0
6.0
6.5
4.25
5.5
5.75
4.75
5.5
6.0
4.75
5.5
6.5
5
6.25
7.25
Mixed Fine
Small
Small/Med
Medium
decal142-4366
142-4373
Heavy
decal142-4373

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spray master 34233Spray master 34235Spray master 34237Spray master3423334235 ... Show all