3.
Rotate the strainer bowl counterclockwise and
remove the bowl and screen from the body of
the strainer
(Figure
Note:
Remove the strainer bowl by hand.
Note:
Replace the gasket or screen or both if
these parts are worn or damaged.
Figure 54
1. Strainer bowl
2. Gasket
4.
Allow any residual chemical solution to drain
from the strainer body.
Note:
Dispose of the waste solution according
to local codes and the chemical manufacturer's
instructions.
5.
Use a soft-bristle brush and clean water to clean
the screen and bowl.
6.
Install the screen into the strainer body
54).
7.
Install the gasket and strainer bowl onto the
strainer body, and hand tighten the bowl
54).
54).
3. Screen
4. Strainer body
(Figure
(Figure
Cleaning the Sprayer Nozzles
Service Interval: After each use
1.
Rotate the nozzle cap 90° counterclockwise and
remove the cap from the nozzle body
55).
1. Nozzle body
2. Strainer
2.
Remove the sprayer tip and strainer from the
nozzle body
g311411
Note:
Replace any worn or damaged nozzle
parts.
3.
Use a soft-bristle brush and clean water to clean
the nozzle tip and strainer.
4.
Assemble the strainer into the nozzle body
(Figure
55).
5.
Assemble the sprayer tip into the nozzle cap
(Figure
55).
6.
Install the tip and cap onto the nozzle body
(Figure
55).
Note:
Use the slot to rotate the atomizer
56) of the sprayer tip forward (in-line with the
flow-regulator case of the nozzle body).
45
Figure 55
3. Sprayer tip
4. Nozzle cap
(Figure
55).
(Figure
g311414
(Figure

Hide quick links: