Summary of Contents for Amazone GreenDrill GD200-E
Page 1
Operating manual Catch crop seed drill GreenDrill GD200-E / GD200-H GreenDrill GD500-H / GD500-D Please read this operating manual before initial operation. MG4167 Keep it in a safe place for future use! BAH0054-9 11.17...
Page 3
49 (0) 5405 501-0 E-mail: amazone@amazone.de Spare part ordering Spare parts lists are freely accessible in the spare parts portal at www.amazone.de. Please send orders to your AMAZONE dealer. Formalities of the operating manual Type: ---------------------------------- GreenDrill Document number: ---------------- MG4167 Compilation date: ------------------ 11.17...
Product description .................. 26 Intended use .......................... 27 3.1.1 Approved AMAZONE carrying implements ................27 Technical Specifications ......................28 Rating plate and CE mark ..................... 28 EC Declaration of Incorporation .................... 29 Layout and function ..................
Page 5
Tractor with standard socket (3-pin) ..................61 6.11.5 Tractor without standard socket (3-pin) ................. 61 6.12 Programming by your AMAZONE service partner ..............62 6.12.1 Blower fan drive ........................62 6.12.2 Selecting the seeding shaft gearbox motor ................62 GreenDrill control terminal 5.2 ..............
Page 6
Implement cable connection diagram for implements with electric blower fan ..... 97 7.19.2 Implement cable connection diagram for implements with hydraulic blower fan ....98 7.20 Programming by your AMAZONE service partner ..............99 7.20.1 Opening the program ......................99 7.20.2 Blower fan drive ........................
User information User information The User Information section provides information on use of the operating manual. This operating manual is valid for all versions of the implement. Figures serve as a reference and are to be understood as representations of the principle. All of the equipment is described without indicating it as special optional equipment.
User information Diagrams Instructions and responses Activities to be carried out by the user are given as numbered instructions. Always observe the se- quence of the instructions. If applicable, the reaction to the respective instructions is marked with an arrow. Example: Instruction 1 ...
General safety instructions General safety instructions This section contains supplementary information on the safety advice in the operating manual to en- sure safe operation of the implement. Obligations and liability Comply with the instructions in the operating manual Knowledge of the basic safety information and safety regulations is a basic requirement for safe han- dling and fault-free implement operation.
Page 11
General safety instructions Risks in handling the implement The implement has been constructed to the state-of-the art and the recognised rules of safety. How- ever, operating the implement may cause risks and restrictions to the health and safety of the user or third persons. ...
General safety instructions Representation of safety symbols Safety instructions are indicated by the triangular safety symbol and the highlighted signal word. The signal word (DANGER, WARNING, CAUTION) describes the severity of the risk, and carries the fol- lowing meaning: DANGER Indicates a direct threat at high risk which will result in death or most serious bodily harm (loss of limbs or long-term harm), should it not be prevented.
General safety instructions Organisational measures The operator must provide the necessary personal protective equipment as per the information pro- vided by the manufacturer of the crop protection agent to be used, such as: Safety glasses Protective shoes Chemical-resistant overalls ...
General safety instructions User training Only those people who have been trained and instructed may work with/on the implement. The opera- tor must clearly specify the responsibilities of the people charged with operation and maintenance work. People being trained may only work with/on the implement under the supervision of an experienced person.
General safety instructions Safety measures in normal operation Only operate the implement if all the safety and protection equipment is fully functional. Check the implement at least once a day for visible damage and check the function of the safety and protection equipment.
Immediately replace any implement parts which are not in a perfect state. Use only original AMAZONE spare and wear parts or the parts cleared by AMAZONEN-WERKE so that the operating permit retains its validity in accordance with national and international regulations. If you use wear and spare parts from third parties, there is no guarantee that they have been designed and manufactured in such a way as to meet the requirements placed on them.
General safety instructions 2.13 Warning symbols and other labels on the implement Always keep all the warning symbols of the implement clean and in a legible state. Replace illegible warning symbols. You can obtain the warning symbols from your dealer using the order number (e.g., MD 075).
Page 18
General safety instructions Order number and explanation Warning symbol MD 076 Risk of hands or arms being caught or drawn into the implement due to moving force transmission parts. This hazard can cause the most severe injuries with loss of body parts. Never open or remove protective equipment, ...
Page 19
General safety instructions MD 082 Risk of falling when riding the implement on treads or platforms. Causes serious, potentially fatal injuries any- where on the body. It is forbidden to ride on the implement or climb the implement when it is running. This prohibition also applies to implements with step surfaces or platforms.
General safety instructions MD 102 Danger from intervention in the implement, e.g. installation, adjusting, troubleshooting, cleaning, maintaining and repairing, due to the tractor and the implement being started unintentionally and rolling away. These dangers can cause extremely serious and potentially fatal injuries. ...
General safety instructions 2.14 Safety information for users Switch off control terminal before road transport. before adjustment, maintenance and repair work. Risk of accident due to unintentional starting up of the metering unit or other implement components. 2.14.1 General safety instructions and accident prevention instructions ...
Page 22
General safety instructions Use of the implement Before starting work, make sure that you understand all the equipment and control elements of the implement and their functions. It is too late for this when the implement is already in opera- tion.
Have the hydraulic hose lines checked for proper functioning by a specialist at least once a year. Replace the hydraulic hose lines if they are damaged or worn. Use only original AMAZONE hydraulic hose lines. The hydraulic hose lines should not be used for longer than six years, including any storage time of maximum two years.
General safety instructions 2.14.3 Electrical system When working on the electrical system, always disconnect the battery (negative terminal). Only use the prescribed fuses. If fuses are used that are too highly rated, the electrical system will be destroyed – risk of fire. ...
Disconnect the cable to the tractor generator and battery before performing electrical welding work on the tractor and mounted implements. Spare parts must at least comply with the specified technical requirements of AMAZONEN- WERKE. This is ensured through the use of original AMAZONE spare parts. GreenDrill BAH0054-9 11.17...
Any use other than those listed above, especially mounting the GreenDrill on implements from other manufacturers or AMAZONE implement that are not listed here, is considered as non-intended. Mounting the GreenDrill using the assembly parts that are not intended for the respective implement is also considered non-intended use.
Product description Technical Specifications GreenDrill GreenDrill GreenDrill GreenDrill Catch crop seed drill GD200-E GD200-H GD500-H GD500-D Seed hopper volume [l] Outlets [number] from the Blower fan drive Electric hydraulic hydraulic carrying im- plement Metering unit Metering with electrical metering motor Automatic Only possible with GreenDrill control terminal 5.2.
Any danger for persons due to the mounting of the GreenDrill on the carrying implement must be ruled out in all situations. NOTE AMAZONE is not liable for damage caused by faulty mounting and improper operation of the GreenDrill. The factory plate contains the...
Layout and function Layout and function The GreenDrill is used for spreading catch crops and re-seeding grass. The seed metered by the seed metering wheels is conveyed into the seed hoses (1). An electrically or hydraulically driven blower fan (2) produces the air flow to deliver the seed. The GreenDrill GD500-D is fed by the blower fan of the carrying implement.
Layout and function Metering 4.1.1 Seeding shaft with seed metering wheels The seed metering wheels are selected based on the seed type. You can find the right seed metering wheel to meter your seed in the seed- ing tables in the Appendix. Each seed metering wheel is made up of several smaller units.
Layout and function 4.1.1.2 Seeding shaft with fine seed metering wheels fb-f-fb-fb The seeding shaft (1) with 8 fine seed metering wheels fb-f-fb-fb is used for seed with small grain size with low spread rates, e.g. mustard and buckwheat.
Layout and function 4.1.1.3 Seeding shaft with Flex 20 seed metering wheels The seeding shaft with 8 Flex 20 seed metering wheels is used for seeds such as Peas Beans. 4.1.1.4 Seeding shaft with Flex 40 seed metering wheels The seeding shaft with 8 Flex 40 seed metering wheels is used for seeds such as ...
Layout and function 4.1.2 Seeding shaft speed Control terminal 3.2 An electric motor drives the seeding shaft. The working speed selected for the calibration test must always be maintained, as the speed of the seeding shaft determined with the calibration test does not change.
Layout and function 4.1.4 Calibration test For calibration and when emptying the seed hopper, the seed drops into the collection bag (2) over the chute (1). Always perform a calibration test during the initial operation. when changing the sort. ...
Layout and function Blower fan The blower fan generates a flow of air that conveys the metered material to the baffle plates. The air current becomes stronger with increasing blower fan speed. A strong air current is required for optimal distribution of the seed. If the air flow is too strong, the seed can be damaged on the baffle plates.
Layout and function 4.3.2 Hydraulic blower fan drive If your implement is equipped with the hydraulic blower fan drive, the control terminal shows whether the blower fan is switched on or off. When the blower fan is switched on, the red control lamp above button is illuminated.
Layout and function A measurement strip with a scale shows the housing temperature [°C] of the hydraulic motor. With increasing temperature (from 71°C to 110°C), the scale becomes black. 4.3.3 GreenDrill GD500-D without blower fan drive The GreenDrill GD500-D is not equipped with a blower fan. The air current for the GreenDrill GD500-D is produced by the blower fan of the carrying implement.
Settings before commissioning Settings before commissioning DANGER Danger of crushing, shearing, cutting, being caught or drawn in, winding and knocks through: unintentional lowering of the implement raised using the tractor's 3-point hydraulic system. unintentional lowering of raised, unsecured implement parts.
Settings before commissioning WARNING When using the machine, observe the safety instructions in this operating manual in the operating manual of the carrying implement. CAUTION Never open the seed hopper cover or metering unit cover with the blower fan running. Seed escapes uncontrollably. The seed hopper and metering units form a sealed pressurised sys- tem.
Settings before commissioning 3.1 Hold the ladder and pull on the lever (1). This releases a latch (2) that repre- sents the mechanical transport locking mechanism. 3.2 Unfold the ladder. 5.1.2 Folding the ladder 1. Fold in the ladder (1). Ensure that the ladder engages in the mechanical transport locking mechanism.
Settings before commissioning Switching off the agitator shaft drive 1. Switch off the control terminal. The agitator shaft (1) should be run- ning when using seeds that tend towards bridging. are very light, e.g. grass. 2. Remove the protective cover (1). 2.1 Loosen and remove the 2 hexagonal nuts (2) with the socket wrench (3).
Settings before commissioning Replacing the seeding shaft 1. Switch off the control terminal. 2. Empty the seed hopper. 3. Remove the protective cover (1). 3.1 Loosen and remove the 2 hexagonal nuts (2) with the socket wrench (3). 4. Remove the round belt (1). 5.
Settings before commissioning Seeding with Flex seed metering wheels For the gentle seeding of large seeds, e.g. peas and field beans, the flexible Flex seed metering wheels are used (see section "Seeding tables", page 107). To prevent damage to the Flex seed metering wheels, the air plate (1) must be removed.
Settings before commissioning Preparing the implement for calibration or for emptying the seed hopper 1. Release the star handles (1) and remove the calibration plate (2). 2. Release the star handle (1), push up the chute (2) and re-fasten. 3. Fasten the collection bag (3) on the chute to collect the seed.
Settings before commissioning Hydraulic blower fan drive Before you adjust the blower fan speed, check the program settings, see section 7.20.2, page 100 section 7.20.8, page 103 section 7.20.9, page 103 5.7.1 Connecting the hydraulic hose lines to the tractor The GreenDrill is equipped with a hydraulic con- trol block with control valve (1).
Settings before commissioning Connect the hydraulic hose lines to the tractor hydraulic system as follows: Pressure line Connection with the label to a single-acting tractor control unit with priority. P (red) Return flow line Connection with the label to an unpressurised tractor connection with direct access to the hydraulic T (yellow) fluid tank.
Settings before commissioning 5.7.3 Setting the blower fan speed on tractors without flow control valve Close the control valve (1) of the hydraulic control block before actu- ating the tractor control unit to prevent damage when the blower fan over-revs. 1.
GreenDrill control terminal 3.2 GreenDrill control terminal 3.2 (1) GreenDrill control terminal 3.2 (2) Bracket for the control terminal (3) Power cable for 3-pin tractor standard socket (12-volt). (1) Plug (3-pin) for power supply (2) Signal plug (6-pin) for the implement cable The implement cable connects the control terminal with the GreenDrill.
GreenDrill control terminal 3.2 Control elements (1) Display (6) Switch seeding shaft on/off (2) On/Off button (7) The control lamp is illuminated when the seeding shaft is running (3) The control lamp is illuminated when the control terminal is switched on (8) Increase the seeding shaft speed (4) Switch the electric blower fan drive (9) Decrease the seeding shaft speed...
GreenDrill control terminal 3.2 Initial operation of control terminal 3.2 6.2.1 Switching on the control terminal 1. Instruct any people in the area to stand at a minimum distance of 10 m from the implement. 2. Press the button. The control lamp above the button is illuminated ...
GreenDrill control terminal 3.2 Calibration test Switch off the seeding shaft motor and the blower fan motor. The blower fan cannot be switched on during calibration. 1. Prepare the implement for the calibration test (see section 5.6, page 46). 2. Check that the correct seed metering wheels have been fitted. 3.
GreenDrill control terminal 3.2 Adjusting the blower fan speed (electric blower fan drive) 1. Press and hold the button for 2 seconds. The display flashes the current blower fan speed. 2. Enter the desired blower fan speed with the buttons (e.g.
GreenDrill control terminal 3.2 Starting work at the beginning of the field Do not switch off the blower fan during use. Before starting work 1. Close the seed hopper cover. 2. Check if the deflector plates have the same distance. 3.
GreenDrill control terminal 3.2 Turning at end of the field 1. Press the button. The green control lamp above the button is turned off The seeding shaft stops The blower fan continues to run. 2. Lift the carrying implement, turn, and move back to working position. 3.
GreenDrill control terminal 3.2 6.10 Faults DANGER Before eliminating a fault Read and observe the "Faults" section in the operating manual for the carrying implement Position the combination on a firm, horizontal surface Switch off the seeding shaft and blower fan of the GreenDrill ...
Page 59
GreenDrill control terminal 3.2 In case of a system fault The control terminal shows the fault message in a coded form (see Table, unterhalb) An acoustic signal is issued. Fault mes- Cause Troubleshooting sage Reduce consumer Operating voltage is too low Check the battery and cables Check the alternator Operating voltage is too high...
GreenDrill control terminal 3.2 6.11 Installations and connections – Control terminal 3.2 6.11.1 Installation of the control terminal 3.2 1. Fasten the bracket (1) in the tractor cab with 2 screws. 2. Bend the bracket to ensure optimal reading of the display. 3.
GreenDrill control terminal 3.2 6.11.3 Power connection 6.11.4 Tractor with standard socket (3-pin) Connect the power cable (1) to control terminal and the 3-pin standard socket in the tractor cab. Never connect the 12 volt power supply to the cigarette lighter socket. 6.11.5 Tractor without standard socket (3-pin) If the tractor is not equipped with a 3-pin standard socket, have the battery cable retrofitted on your...
Programming by your AMAZONE service partner This section explains the programming of the implement configuration on control terminal 3.2. Have the programming performed by your AMAZONE service partner. Before each setting, first switch off the seeding shaft motor and then the blower fan motor.
GreenDrill control terminal 5.2 GreenDrill control terminal 5.2 (1) GreenDrill control terminal 5.2 (2) Bracket for the control terminal (3) Power cable for 3-pin tractor standard socket (12-volt) (1) Socket (3-pin) for power supply (2) Signal socket (6-pin) for the implement cable The implement cable connects the control terminal with the GreenDrill.
GreenDrill control terminal 5.2 Control elements (1) Graphic display (6) Switch seeding shaft on/off (2) On/Off button (7) The control lamp is illuminated when the seeding shaft is running (3) The control lamp is illuminated when the control terminal is switched on (8) Increase the seeding shaft speed (4) Switch the electric blower fan drive (9) Decrease the seeding shaft speed...
GreenDrill control terminal 5.2 Initial operation of control terminal 5.2 7.2.1 Switching on the control terminal 1. Instruct any people in the area to stand at a minimum distance of 10 m from the implement. 2. Press the button. The control lamp above the button is illuminated ...
GreenDrill control terminal 5.2 Main menu 7.3.1 During operation - Display without speed sensor Line 1 in the main menu shows the seeding shaft speed [%] set for calibration. Line 2 in the main menu shows the forward speed [km/h] set for calibration. The seeding shaft speed is not adjusted for chang- ing forward speeds.
GreenDrill control terminal 5.2 7.3.3 During operation - Changing the spread rate In the main menu, the seeding shaft speed and therefore the spread rate can be changed in 1 %-increments during operation. The spread rate is increased by pressing the button.
GreenDrill control terminal 5.2 Submenus With the buttons, the following submenus can be called up from the main menu: 1. Language 2. Operating voltage 3. Hectare counter 4. Working hour counter 5. Emptying the seed hopper 6. Calibration (kg/ha or grains/m 7.
GreenDrill control terminal 5.2 Calibration [kg/ha and grains/m The seed calibration can be terminated at any time by pressing the button or button. The blower fan cannot be switched on during calibration. 1. Prepare the implement for the calibration test (see section 5.6, page 46). 2.
GreenDrill control terminal 5.2 7.6.1 Calibration [kg/ha] 1. Make all of the entries shown in section 7.6, page 69. 2. Select the display with the buttons. 3. Confirm the selection with the button. 4. Enter the desired spread rate with the buttons (e.g.
Page 71
GreenDrill control terminal 5.2 10. Select the display with the buttons. 11. Confirm the selection with the button. The calibration starts. The seeding shaft begins to rotate (without blower fan). The seeding shaft stops automatically after the set time has elapsed.
GreenDrill control terminal 5.2 7.6.2 Calibration [grains/m 1. Make all of the entries shown in section 7.6, page 69. 2. Select the display with the buttons. 3. Confirm the selection with the button. 4. Enter the desired spread rate (e.g. 100 grains/m with the buttons.
Page 73
GreenDrill control terminal 5.2 14. Select the display with the buttons. 15. Confirm the selection with the button. 1)2) 16. Enter the desired duration for the calibration test with buttons (e.g. 0.5 min). 17. Confirm the entry with the button. Calibrate for 0.5 minutes for seeds, e.g., wheat, barley, peas and large spread rates Calibrate for 1.0 minute...
GreenDrill control terminal 5.2 20. Weigh the collected seed. 21. Select the display with the buttons. 22. Confirm the selection with the button. 23. Enter the weight [kg] of the collected seed on the control termi- nal using the buttons (e.g. 3.25 kg). 24.
GreenDrill control terminal 5.2 Calibration (pulses/100 m) The calculation requires the "pulses/100 m" calibration value the travel speed [km/h]. the worked area [ha] (hectare counter). the seeding shaft speed. If the calibration value is not known, it must be determined by means of a "Pulses per 100 m" calibra- tion run.
GreenDrill control terminal 5.2 7.7.1 Calibration by driving a calibration distance 1. On the field, measure out a calibration distance of exactly 100 m. Mark the start and end point of the calibration distance. 2. Drive the tractor to the starting position and put the carrying im- plement into working position.
GreenDrill control terminal 5.2 7.7.2 Calibration by comparing the speedometer 1. Select the display with the buttons. 2. Confirm the selection with the button. 3. Select the display with the buttons. 4. Confirm the display with the button. 5. Start the tractor for the calibration run. During the calibration run, compare the speeds shown on the display with those on the tractor's speedometer.
GreenDrill control terminal 5.2 7.7.4 Restoring the factory setting for the calibration value (reset) 1. Select the display with the buttons. 2. Confirm the selection with the button. 3. Select the display with the buttons. 4. Confirm the display with the button.
GreenDrill control terminal 5.2 Hectare counter Area calculation is carried out using the "actual" forward speed values. The control terminal must be connected to the 7-pin tractor signal socket (see section 7.18.4.1, page 93) or to the radar device (see section 7.18.4.3, page 95) or ...
GreenDrill control terminal 5.2 7.10 Adjusting the blower fan speed (electric blower fan drive) 1. Select the display with the buttons. 2. Confirm the selection with the button. 3. Select the display with the buttons. 4. Confirm the selection with the button.
GreenDrill control terminal 5.2 7.13 Starting work at the beginning of the field Do not switch off the blower fan during use. Before starting work 1. Close the seed hopper cover. 2. Check if the deflector plates have the same distance. 3.
GreenDrill control terminal 5.2 7.14 Turning at end of the field Turning with position signal (working/transport position) The turning procedure takes place automatically when the implement receives the following signals: The implement is in working position The implement is in transport position. To do so, the implement must ...
GreenDrill control terminal 5.2 7.15 Fill level control A low level sensor (1) monitors the seed level in the seed hopper. If the seed level reaches the low level sensor, an acoustic signal is emitted. At the same time, the control terminal displays a warning message.
GreenDrill control terminal 5.2 7.16 Emptying the seed hopper The seed hopper can be emptied through the menu controls or with the calibration button. 7.16.1 Emptying the seed hopper through the menu controls 1. Prepare the implement for emptying the seed hopper (see sec- tion 5.6, page 46).
GreenDrill control terminal 5.2 7.17 Error messages Error message Description Remedy Control voltage is too low Contact the service partner Operating voltage Minimise the consumers (at least 10 volt) Check the battery undercut, Check the alternator see section "7.12", page 80 ...
Page 86
GreenDrill control terminal 5.2 Error message Description Remedy The calibration distance Repeat the calibration, is too short (see section 7.7, page 75) "pulses/100 m" The seeding shaft speed is too Use seed metering wheels with low. a smaller volume Display seeding shaft with fewer seed during seed calibration metering wheels...
Page 87
GreenDrill control terminal 5.2 Error message Description Remedy The seeding shaft is not rotating Switch off control terminal. Check whether any foreign ob- jects are hindering the rotation of the seeding shaft or agitator shaft. Switch off control terminal. The seeding shaft motor ...
Page 88
GreenDrill control terminal 5.2 Error message Description Remedy The blower fan is not rotating Switch off control terminal. Check if foreign objects are hindering rotation of the blower fan the calibration plate is installed wrong (see section 5.6, page 46) Switch off control terminal.
Page 89
GreenDrill control terminal 5.2 Fault Possible fault elimination Change the lifting unit signal Seeding shaft rotates (see section 0, page 102) in transport position Switch on the seeding shaft and start driving Seeding shaft does not rotate in working position ...
Page 90
GreenDrill control terminal 5.2 Continuous or occasional for- The speed signal is not being detected ward speed display: 0.0 km/h Set the signal in section 7.20.4 to NO, if all of the settings in the sections section 7.20.4, section 7.20.5, section 7.20.6, section 0 and section 100) are set to AUTO.
GreenDrill control terminal 5.2 7.18 Installations and connections – Control terminal 5.2 7.18.1 Installation of the control terminal 5.2 Fasten the bracket (1) in the tractor cab with 2 screws. Bend the bracket so as to provide optimum read- ing of the display. Insert the control terminal on the bracket in the tractor cab.
GreenDrill control terminal 5.2 7.18.3 Power cable connection 7.18.3.1 Tractor with standard socket (3-pin) Connect the power cable (1) to control terminal and the 3-pin standard socket in the tractor cab. Never connect the 12 volt power supply to the cigarette lighter socket. 7.18.3.2 Tractor without standard socket (3-pin) If the tractor is not equipped with a 3-pin standard socket, have the battery cable retrofitted on your tractor at a specialist workshop.
GreenDrill control terminal 5.2 7.18.4 Signal sources The control terminal shows the forward speed [km/h] and adjusts the seeding shaft speed according to the changing forward speed. The seed rate [kg/ha] remains unchanged even at varying forward speeds. If it is set correctly, speed differences of 50 % are adjusted up or down. When the implement is raised, e.g., when turning at the end of the field, the seeding shaft automatical- ly stops rotating.
GreenDrill control terminal 5.2 7.18.4.2 Working position sensor The working position sensor (1) is required when the tractor has a 7-pin signal socket that does not emit a "Working position" signal [see section "Tractor signal socket (7-pin)", page 93]. The working position sensor (1) can be attached on the tractor three-point or on the swivelling running gear of the carrying implement.
GreenDrill control terminal 5.2 7.18.4.3 Measuring the forward speed with the radar device If the tractor does not have a 7-pin signal socket, control terminal 5.2 requires a working position sensor (see section "Working position sensor", page 94) and ...
GreenDrill control terminal 5.2 7.18.4.4 Measuring the forward speed with the GPS device If the tractor does not have a 7-pin signal socket, control terminal 5.2 requires a working position sensor (see section "Working position sensor", page 94) and ...
5.2. The functions can only be activated when the implement configuration is programmed on the control terminal. Have the programming performed by your AMAZONE service partner. Before making any settings, switch off the blower fan motor and seed- ing shaft motor.
GreenDrill control terminal 5.2 7.20.2 Blower fan drive Setting with electric blower fan drive: ......YES Setting with hydraulic blower fan drive: ......NO Change the parameters using the buttons. 7.20.3 Seeding shaft signal tone An acoustic warning tone is issued when the seeding shaft is switched on and off.
GreenDrill control terminal 5.2 7.20.6 Signal sources The control terminal 5.2 requires several signals. The signals are provided either by 7-pin tractor sig- nal socket or the signals come from other sources. The source must be named in the control terminal. Forward speed signal source [km/h] The following sources can, if equipped, deliver the "Forward speed [km/h]"...
Page 102
GreenDrill control terminal 5.2 Entry of the forward speed signal source [km/h] The control terminal receives the "Actual forward speed [km/h]" signal through one of the 3 connections: Connection on the 7-pin tractor signal socket or Connection on the radar device or ...
GreenDrill control terminal 5.2 7.20.7 Acoustic warning signal In case of an error message during operation, an acoustic warning signal is emitted ....ON no acoustic warning signal is emitted ..... OFF Change the parameters using the buttons. 7.20.8 Seeding shaft gearbox motor The GreenDrill with 8 outlets has a .......
GreenDrill control terminal 5.2 7.20.10 Calibrat. button The GreenDrill has a calibration button (see section 7.6.3, 74). page Change the parameters using the buttons. 7.20.11 Systems of units Display Metric system ........(m, ha, km/h, kg) Anglo-American system ....
Cleaning, maintenance and repairs Cleaning, maintenance and repairs DANGER Danger of crushing, shearing, cutting, being caught or drawn in, winding and knocks through: unintentional lowering of the implement raised using the tractor's 3-point hydraulic system. unintentional lowering of raised, unsecured implement parts.
Cleaning, maintenance and repairs First operation Tighten all bolted connections after approx. 20 operating hours, then check these connections every 250 operating hours. Cleaning 1. Empty the seed hopper and metering units. 2. Remove the seeding shaft to thoroughly clean the metering unit. 3.
Seeding tables Seeding tables The seeding table values are reference values that can change due to grain shape, grain size, thousand grain weight, and dressing. The exact seeding shaft speed for the re- quired spread rate is derived from the calibration values. ...
Need help?
Do you have a question about the GreenDrill GD200-E and is the answer not in the manual?
Questions and answers