Keysight Technologies U2941A Operating Manual

Parametric test fixture

Advertisement

Quick Links

Keysight U2941A Parametric
Test Fixture
Operating
Guide

Advertisement

Table of Contents
loading

Summary of Contents for Keysight Technologies U2941A

  • Page 1 Keysight U2941A Parametric Test Fixture Operating Guide...
  • Page 2 Keysight U2941A Operating Guide...
  • Page 3 Keysight U2941A Operating Guide...
  • Page 4 IMPLIED, WITH REGARD TO THIS agreement and written consent from customarily provided to the public. MANUAL AND ANY INFORMATION Keysight Technologies as governed by Accordingly, Keysight provides the CONTAINED HEREIN, INCLUDING BUT United States and international Software to U.S. government NOT LIMITED TO THE IMPLIED copyright laws.
  • Page 5: Safety Symbols

    Caution, risk of danger (refer to this Earth (ground) terminal manual for specific Warning or Caution information) Protective conductor terminal Caution, hot surface Frame or chassis terminal Out position of a bi-stable push control Equipotentiality In position of a bi-stable push control Keysight U2941A Operating Guide...
  • Page 6: General Safety Information

    – Applying excessive voltage or overloading the device will cause CAUTION irreversible damage to the circuitry. – Use the device with the cables provided. – Repair or service that is not covered in this manual should only be performed by qualified personnel. Keysight U2941A Operating Guide...
  • Page 7: Environmental Conditions

    The table below shows the general environmental requirements for this instrument. Environmental cond itions Requirements Operating temperature 0 °C to 50 °C Operating humidity 20% to 85% RH noncondensing Storage temperature –20 °C to 70 °C Storage humidity 5% to 90% RH noncondensing Keysight U2941A Operating Guide...
  • Page 8: Waste Electrical And Electronic Equipment (Weee) Directive 2002/96/Ec

    To contact Keysight for sales and technical support, refer to the support links on the following Keysight websites: – www.keysight.com/find/clampmeter (product-specific information and support, software and documentation updates) – www.keysight.com/find/assist (worldwide contact information for repair and service) Keysight U2941A Operating Guide...
  • Page 9: Table Of Contents

    ..........31 Keysight U2941A Operating Guide...
  • Page 10 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight U2941A Operating Guide...
  • Page 11: Introduction

    Introduction The Keysight U2941A Parametric Test Fixture is designed for semiconductor device testing. The U2941A has three input channels and a common ground. You can select different types of socket modules for devices-under-test (DUTs) of various pin configurations. By mounting the suitable socket module on the U2941A, you are able to connect the DUTs to the U2722A/U2723A USB modular source measure unit and U2751A USB modular switch matrix.
  • Page 12 You also have the option to connect the U2722A/U2723A via the U2751A to the U2941A as shown below. U2751A High Row 1 O – Row 2 High S – Column 1 Column 2 U2722A/ High Low High Low U2723A BNC male outer contact (black wire) O –...
  • Page 13: Product At A Glance

    Product at a Glance Product outlook (with closed cover) Top view Input connectors Common ground connector Front view Keysight U2941A Operating Guide...
  • Page 14: Product Outlook (With Opened Cover)

    Rear view Kensington lock Product outlook (with opened cover) Top view Terminals Socket module Keysight U2941A Operating Guide...
  • Page 15: Product Dimensions

    Product dimensions Top view 250 mm 53 mm 200 mm Front view 120 mm Keysight U2941A Operating Guide...
  • Page 16: Standard Shipped Items

    Standard Shipped Items Verify that you have received the following items with your U2941A. If anything is missing or damaged, please contact the nearest Keysight Sales Office. 4 Assembly PTFE plate 4 28-pin dual-in-line package socket module 4 0.1 inch universal socket module 4 0.075 inch universal socket module...
  • Page 17: Orderable Items

    Four pin plug to miniature clip cables (black) U2941A-105 U2941-20005 Four pin plug to miniature clip cables (red) U2941A-106 U2941-20006 Four pin plug to miniature clip cables (blue) U2941A-107 U2941-61601 Three BNC to two-wire cables, 1 m Keysight U2941A Operating Guide...
  • Page 18: Connection Cables

    3 Push the cable casing towards the connector until it firmly envelops the connector. 4 Connect the BNC ends of the cables to the U2941A input connectors. To connect the U2722A/U2723A via the U2751A to the U2941A, use the U2922A terminal block.
  • Page 19 ≈ 220 mm 4.5 mm 4.5 mm 1 mm 1 mm – Pin plug to miniature clip cable Residual Resistance: 12 mΩ typical Black: U2941-20004 Red: U2941-20005 Blue: U2941-20006 ≈ 200 mm 4.5 mm 40.8 mm 1 mm Keysight U2941A Operating Guide...
  • Page 20: Socket Modules

    U2722A/U2723A. 42.8 mm 85.6 mm 83.6 mm – 28-pin dual-in-line package (U2941-60003) This socket module has a 28-pin dual-in-line lever actuated zero insertion force (ZIF) socket. 42.8 mm 85.6 mm 83.6 mm Keysight U2941A Operating Guide...
  • Page 21 This socket module is used for measurement of virtually any device such as components, DIP IC, CPGA package, or any small-scale circuit. 42.8 mm 85.6 mm 83.6 mm Jumper pin (U2941-20008) It is used with the universal socket module. 0.5 mm 8 mm Keysight U2941A Operating Guide...
  • Page 22: Hardware Installation

    U2941A. Black plastic fasteners Socket module Use the following procedure to attach the socket module. Ensure that no voltage or current is applied to the U2941A when attaching the NOTE socket module. 1 Open the lid of the U2941A.
  • Page 23 Use the following procedure to remove the socket module from the U2941A. Ensure that no voltage or current is applied to the U2941A when removing the NOTE socket module. 1 Open the lid of the U2941A. 2 Remove the connection cables.
  • Page 24: Mounting And Wiring The Dut On The Socket Module

    U2941A and the desired terminals on the socket module. Kelvin connections Connect a pin plug to pin plug cable between the Output terminal on the U2941A and the desired terminal on the socket module, and then connect a pin plug to miniature clip cable between the Sense terminal and DUT lead.
  • Page 25 Connected to the O – Connected to the S+ terminal terminal Connected to the S – Connected to the O+ terminal terminal Keysight U2941A Operating Guide...
  • Page 26 Ensure that the DUT is placed on the assembly PTFE plate. Connected to the O+ terminal Connected to the O – terminal Assembly PTFE plate Keysight U2941A Operating Guide...
  • Page 27 The provided pitch sizes (0.1 inch, 0.075 inch, and 0.05 inch) offer you the flexibility to mount your DUT on the U2941A. You may either solder the DUT directly or insert an IC holder on the universal socket module. Open the casing of the socket module by removing the screws and use a wire to connect the DUT lead or IC holder lead to the jumper pin which is inserted on the socket module.
  • Page 28: Software Installation

    Software Installation The Parametric Measurement Manager extends the capabilities of the U2941A by allowing you to perform various types of measurements efficiently. System requirements Before installing the Parametric Measurement Manager, ensure that your PC meets the following minimum system requirements for installation and operation.
  • Page 29: Installing The Parametric Measurement Manager

    14 Click Finish when the installation has completed. 15 A shortcut to the Parametric Measurement Manager will be created to your desktop. Refer to the Keysight U2941A Parametric Measurement Manager Application NOTE Software Help File for more information on the software features and functions.
  • Page 30: Product Specifications

    20% to 85% RH noncondensing Storage humidity 5% to 90% RH noncondensing Altitude Up to 2000 m PHYSICAL SPECIFICATIONS Dimensions (W × D × H) 250 mm × 200 mm × 120 mm Weight ≈ 1.33 kg Warranty 3 months Keysight U2941A Operating Guide...
  • Page 31: Maintenance

    Maintenance To maintain high performance, the U2941A must be kept clean. Oil, perspiration, hair, dust, and dirt will degrade board insulation, which increases leakage current and decreases measurement accuracy. Keysight recommends the following cleaning procedures. Chassis, lid, inner plate, and socket modules 1 Ensure that voltage or current is not applied to the U2941A.