Lucid Ada 88192 Converter Settings For Local Control - HP XW9400 Hardware Setup Manual

Autodesk visual effects and finishing 2009 edition
Hide thumbs Also See for XW9400:
Table of Contents

Advertisement

Lucid ADA 88192 Converter Settings for Local
Control
You must configure the following settings to control the converter locally.
Any setting not listed here either has no effect with the application or can be
set to any of the values available for it.
Menu
ADAT
AES
Analog
Analog INs:
SoftClip
Analog
Analog INs: Gain
Analog
Analog OUTs: Level
Meter
Route
Sync
Menu Item
ADAT INs: SRC ONADAT
INs: SMUX OFF
AES IN1+2: SRC OFF
AES IN3+4: SRC OFF
AES IN5+6: SRC OFF
AES IN7+8: SRC OFF
IN1+2: SoftClip ON
IN3+4: SoftClip ON
IN5+6: SoftClip ON
IN7+8: SoftClip ON
set each input channel to
a value in the range -95.5
to +31.5 dB
set either -10 or +4 for
each output channel
Clip Detect: 3
For analog audio:
AES INs --> ADAT OUTs
Analog INs --> AES OUTs
AES INs --> Analog OUTs
For digital audio:
AES INs --> ADAT OUTs
AES INs --> AES OUTs
AES INs --> ANALOG
OUT
Internal OFF
External AES 1+2

Lucid ADA 88192 Converter Settings for Local Control | 45

Comment
3 is the recommended setting
If these options do not appear, verify
that Route Unit (in the System, Mis-
cellany menu) is set to 8.
External AES 1+2 is the recommen-
ded setting.