HP XW9400 Hardware Setup Manual page 23

Autodesk visual effects and finishing 2009 edition
Hide thumbs Also See for XW9400:
Table of Contents

Advertisement

TIP If the DKU has already been installed on the workstation, you can access
its contents in the /usr/discreet/DKU directory, without having to use the
application DVD.
4 Run the info command to scan the DVI-Ramp's current firmware. Type:
./info
The output is similar to the following example:
Versions:
Hardware = <Hardware Version>
Micro = <Firmware version>
Genlock = 3.21
DVI = 4.01
FrameBuffer = 4.05
SDI = 4.10
Where
<Hardware Version>
hardware, and
in the DVI ramp. If the firmware version does not match the hardware
version listed in the table that precedes this procedure, you must perform
the firmware update procedure.
Updating the DVI-Ramp Firmware
The firmware on your DVI-Ramp must correspond to the certified version
required by your Visual Effects and Finishing application version. If you verified
the firmware on your DVI-Ramp and it did not match the certified version,
you must update it. The following procedure describes how to update the
firmware version of the DVI-Ramp.
To update the DVI-Ramp firmware:
1 Open a terminal, log in as root, and go to the
DKU_<
version_number
application DVD, where
of the DKU. For example:
cd /mnt/cdrom/DKU_3.0.0/Utils/DVI_firmwareUpdate/
TIP If the DKU has already been installed on the workstation, you can access
its contents in the /usr/discreet/DKU directory, without having to use the
application DVD.
is the current version of the DVI-Ramp
<Firmware version>
>/Utils/DVI_firmwareUpdate directory of the
<version_number>
is the firmware currently loaded
represents the version
DVI-Ramp Firmware | 15

Advertisement

Table of Contents
loading