Purpose: The document is intended for use by end-of-life recyclers or treatment facilities. It provides the basic instructions
for the disassembly of HP products to remove components and materials requiring selective treatment, as defined by EU
directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE).
1.0 Items Requiring Selective Treatment
1.1 Items listed below are classified as requiring selective treatment.
1.2 Enter the quantity of items contained within the product which require selective treatment in the right column, as
applicable.
Item Description
Printed Circuit Boards (PCB) or Printed Circuit
Assemblies (PCA)
Batteries
Mercury-containing components
Liquid Crystal Displays (LCD) with a surface greater
than 100 sq cm
Cathode Ray Tubes (CRT)
Capacitors / condensers (Containing PCB/PCT)
Electrolytic Capacitors / Condensers measuring
greater than 2.5 cm in diameter or height
External electrical cables and cords
Gas Discharge Lamps
Plastics containing Brominated Flame Retardants
Components and parts containing toner and ink,
including liquids, semi-liquids (gel/paste) and toner
Components and waste containing asbestos
Components, parts and materials containing
refractory ceramic fibers
Components, parts and materials containing
EL-MF877-00
Template Revision A
Notes
With a surface greater than 10 sq cm.
There are two in the power supply, one graphics
card, and one system board. (Additional cards may
be present depending on the configuration.)
All types including standard alkaline and lithium coin
or button style batteries.
For example, mercury in lamps, display backlights,
scanner lamps, switches, batteries
Includes background illuminated displays with gas
discharge lamps.
Fifteen attached to the power supply boards.
Include the cartridges, print heads, tubes, vent
chambers, and service stations.
438710-001
Quantity
of items
included
in product
4
1
None
None
None
None
15
None
None
None
None
None
None
None
Page 1

Advertisement

loading

Summary of Contents for HP XW9400

  • Page 1: Hp Xw9400 Workstation

    Purpose: The document is intended for use by end-of-life recyclers or treatment facilities. It provides the basic instructions for the disassembly of HP products to remove components and materials requiring selective treatment, as defined by EU directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE).
  • Page 2 radioactive substances Liquid Fluid in the liquid cooling unit of the optional configurations. 2.0 Tools Required List the type and size of the tools that would typically be used to disassemble the product to a point where components and materials requiring selective treatment can be removed. Tool Description Tool Size (if applicable)
  • Page 3 3.2 Workstation Disassembly Procedures Remove/disengage any security devices that prohibit opening the workstation. Disconnect the power cord from the electrical outlet and then from the workstation. Disconnect all peripheral device cables from the workstation. Remove the access panel. Pull up on the handle 1 and lift off the cover 2. Disconnect all internal cables from system board, power supply, and other components.
  • Page 4 Remove the system battery. On the system board, press on the release tab of the battery holder. Rotate the battery enough to get beyond the latch, and lift it straight up. Battery EL-MF877-00 Page 4 Template Revision A 438710-001...
  • Page 5 Remove the graphics card and any other expansion cards. If necessary, remove PCI holders. For short or tall PCI cards press in on the sides 1 of the holder and rotate it 2 out of the chassis. Short card Tall card Remove the PCI retainer by pressing down on it, then out 1.
  • Page 6 Remove the CPU Heatsink. Remove the CPU airflow duct by lifting up on the tabs 1 and rotating the duct away 2 from the CPU heatsinks. Disconnect the CPU heatsink fan connector 1 from the system board. Loosen the heatsink mounting screws 2.
  • Page 7 Remove the power supply from the chassis. Remove the four screws 1 from the back panel. Slide the power supply toward the front and lift up 2 to remove it from the chassis. 10. If the workstation is equipped with a liquid cooling unit, see section 3.4 for instructions on draining the fluid.
  • Page 8 3.3 Power Supply Disassembly Procedures Cut the cable tie at the rear of the unit. Remove the eight power supply screws—three on each side of the front, one at the side, and one at the top back. EL-MF877-00 Page 8 Template Revision A 438710-001...
  • Page 9 Slide the chassis housing from the power supply unit. Remove the four screws from the corners of the first PCB card. Pull the card loose from the chassis. EL-MF877-00 Page 9 Template Revision A 438710-001...
  • Page 10 Unplug the connectors that connect the two PCB cards together. Remove the first PCB card from the chassis. EL-MF877-00 Page 10 Template Revision A 438710-001...
  • Page 11 Use a diagonal cutter to remove the desired components from both PCB cards. (Note that some components may need to be unsoldered if a diagonal cutter does not fit between the component and the PCB card.) Dispose of all removed components according to regulatory requirements. EL-MF877-00 Page 11 Template Revision A...
  • Page 12 3.4 Draining the liquid cooling unit If your workstation has a liquid cooling unit, follow the procedures below to remove the cooling unit from the workstation and drain the coolant. Disconnect power from the workstation and remove the access panel. Loosen the two liquid cooling unit/CPU 0 mounting screws (1) from the liquid cooling unit.
  • Page 13 Alternately and evenly loosen the two liquid cooling unit/CPU 1 mounting screws from the liquid cooling unit. Lower the fan/radiator to its closed position. For convenience, disconnect the PSU (1) cable from the system board. Disconnect the liquid cooling unit pump cable (2) from the system board. Press the green tab in on the memory fan housing (1) and lift the unit from the system board (2).
  • Page 14 Cut all hoses and remove them from the cooling unit Drain the coolant from the unit and dispose of it according to regulatory requirements. (Refer to Appendix: Cooling Fluid MSDS for a description of the fluid composition.) Return to section 3.2 Workstation Disassembly Procedures to complete the workstation disassembly.
  • Page 15 Appendix: Cooling Fluid MSDS EL-MF877-00 Page 15 Template Revision A 438710-001...
  • Page 16 EL-MF877-00 Page 16 Template Revision A 438710-001...