Lucid Ada 88192 Converter Settings For Remote Control; Lucid Ada 88192 Converter Settings For Local Control - HP xw8600 Workstation Hardware Setup Manual

Autodesk visual eff ects, finishing, and colour grading
Hide thumbs Also See for xw8600 Workstation:
Table of Contents

Advertisement

Lucid ADA 88192 Converter Settings for Remote Control

You must configure the following settings to control the converter remotely. Any setting not listed here
either has no effect with the application or can be set through the audio preferences of the application.
Menu
ADAT
AES
Analog
Analog INs: SoftClip
Meter
System
Miscellany

Lucid ADA 88192 Converter Settings for Local Control

You must configure the following settings to control the converter locally. Any setting not listed here either
has no effect with the application or can be set to any of the values available for it.
Menu
ADAT
AES
Analog
Analog INs: SoftClip
Analog
Analog INs: Gain
Analog
Analog OUTs: Level
Meter
Route
28 | Chapter 5 Setting Up Audio Hardware
Menu Item
ADAT INs: SRC ON
ADAT INs: SMUX OFF
AES IN1+2: SRC OFF
AES IN3+4: SRC OFF
AES IN5+6: SRC OFF
AES IN7+8: SRC OFF
IN1+2: SoftClip OFF
IN3+4: SoftClip OFF
IN5+6: SoftClip OFF
IN7+8: SoftClip OFF
Clip Detect: 3
Route Unit: 8
Menu Item
ADAT INs: SRC ON
ADAT INs: SMUX OFF
AES IN1+2: SRC OFF
AES IN3+4: SRC OFF
AES IN5+6: SRC OFF
AES IN7+8: SRC OFF
IN1+2: SoftClip ON
IN3+4: SoftClip ON
IN5+6: SoftClip ON
IN7+8: SoftClip ON
set each input channel to a value in
the range -95.5 to +31.5 dB.
set either -10 or +4 for each output
channel.
Clip Detect: 3
For analog audio:
AES INs --> ADAT OUTs
Analog INs --> AES OUTs
AES INs --> Analog OUTs
Comment
3 is the recommended setting.
8 is the recommended setting.
Comment
3 is the recommended setting.
If these options do not appear, verify that Route Unit
(in the System, Miscellany menu) is set to 8.