Page 1
PNOZ mmc1p Configurable compact control systems PNOZmulti Mini Operating Manual 1002102-EN-02...
Page 2
Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
Introduction Introduction Validity of documentation This documentation is valid for the product PNOZ mmc1p. It is valid until new documenta- tion is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
Page 6
Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PNOZ mmc1p 1002102-EN-02...
Scope of supply Expansion module PNOZ mmc1p Jumper Unit features Using the product PNOZ mmc1p: Communication module for connection to a base unit from the configurable control systems PNOZmultiMini. The product has the following features: Can be configured in the PNOZmulti Configurator...
Safety Safety Intended use The expansion module PNOZ mmc1p is used for communication of the configurable control systems PNOZmulti Mini via Ethernet. The expansion module may only be connected to a base unit PNOZmulti Mini (for details of the base units PNOZmulti Mini that can be connected, refer to the document "PNOZmulti System Expansion").
Do not open the housing or make any unauthorised modifications. Please make sure you shut down the supply voltage when performing maintenance work (e.g. exchanging contactors). Operating Manual PNOZ mmc1p 1002102-EN-02...
Function description Function description Unit properties The product PNOZ mmc1p has two Ethernet interfaces to Download the project Read the diagnostic data Set virtual inputs for standard functions Read virtual outputs for standard functions via Ethernet (TCP/IP, Modbus/TCP). Information on diagnostics via the Ethernet interfaces can be found in the document entitled "...
Damage due to electrostatic discharge! Electrostatic discharge can damage components. Ensure against discharge before touching the product, e.g. by touching an earthed, conductive sur- face or by wearing an earthed armband. Dimensions 100 (3,94") 22,5 (0.88") Operating Manual PNOZ mmc1p 1002102-EN-02...
Please refer to the document "PNOZmulti System Expansion" for details of the number of modules that can be connected to the base unit and the module types. Operating Manual PNOZ mmc1p 1002102-EN-02...
PNOZmulti Configurator. Proceed as described in the operat- ing instructions for the base unit. NOTICE For the commissioning and after every program change, you must check whether the safety devices are functioning correctly. Operating Manual PNOZ mmc1p 1002102-EN-02...
Appropriate design measures should be used to ensure that the plug-in connection is insensitive to in- creased mechanical stress (e.g. through shock, vibration). Such measures include fixed routing with strain relief, for example. Operating Manual PNOZ mmc1p 1002102-EN-02...
The RJ45 interfaces on the internal autosensing switch enable process data to be ex- changed with other Ethernet subscribers within a network. The product PNOZ mmc1p can also be connected to Ethernet via a hub (hub or switch). Ethernet subscriber...
The LEDs “POWER”, “DIAG”, “FAULT”, “IFAULT” and “OFAULT” will light up on the base unit. The safety system PNOZmulti is ready for operation when the "POWER" and "RUN" LEDs on the base unit and the "POWER" LED on the PNOZ mmc1p are lit continuously. 7.1.1 Display elements for device diagnostics...
You can reset the base unit's Ethernet connection settings to the default settings. Proceed as follows: Switch off the supply voltage Remove the chip card Restart the base unit without the chip card inserted. The Ethernet connection settings are now reset to the default settings. Operating Manual PNOZ mmc1p 1002102-EN-02...
Page 20
10,0 - 150,0 Hz Acceleration Shock stress In accordance with the standard EN 60068-2-27 Acceleration Duration 11 ms Max. operating height above sea level 2000 m Airgap creepage Overvoltage category Pollution degree Rated insulation voltage 30 V Operating Manual PNOZ mmc1p 1002102-EN-02...
Page 21
Max. cable length Max. cable length per input 0,1 km Material Bottom Front Dimensions Height 100,0 mm Width 22,5 mm Depth 120,0 mm Weight 100 g Where standards are undated, the 07/2010 latest editions shall apply. Operating Manual PNOZ mmc1p 1002102-EN-02...
Page 22
Order No. PNOZ mmc1p ETH Expansion module 772 030 Accessories Terminator, jumper Product type Features Order No. PNOZ s terminator plug Terminator, yellow, 10 pieces 750 010 PNOZ s connector Jumper, 10 pieces 750 020 Operating Manual PNOZ mmc1p 1002102-EN-02...
Page 23
Front cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30...