2-2-2 Multifunctional Controller ST4-C12EX

14. Muting input S-D indicator (Orange)
13. Muting input S-C indicator (Orange)
12. Muting input S-B indicator (Orange)
11. Muting input S-A indicator (Orange)
2. Receiver
connector area
1. Emitter
connector area
3. Power indicator (Green)
4. Fault display (Red)
5. Interlock indicator (Yellow)
6. Emission halt indicator (Orange)
Designation
1
Emitter connector area
2
Receiver connector area
3
Power indicator (Green)
4
Fault display (Red)
5
Interlock indicator (Yellow)
6
Emission halt indicator (Orange) Lights up while the emission halt function is valid.
7
Control output indicator (Green) Lights up while the control output (OSSD 1 / 2) is ON.
Auxiliary output 1 indicator
8
(Orange)
Auxiliary output 2 indicator
9
(Orange)
Auxiliary output 3 indicator
10
(Orange)
Muting input S-A indicator
11
(Orange)
Muting input S-B indicator
12
(Orange)
Muting input S-C indicator
13
(Orange)
Muting input S-D indicator
14
(Orange)
Muting input S-E indicator
15
(Orange)
Muting input S-F indicator
16
(Orange)
Output polarity selection
17
switch
14
17. Output polarity selection switch
16. Muting input S-F indicator (Orange)
15. Muting input S-E indicator (Orange)
9. Auxiliary output 2 indicator (Orange)
10. Auxiliary output 3 indicator (Orange)
8. Auxiliary output 1 indicator (Orange)
7. Control output indicator (Green)
Connects the emitter of ST4-A□.
Connects the receiver of ST4-A□.
Lights up while power is ON.
7-segment lights up when an error occurs.
For details, refer to "Chapter 5 Troubleshooting."
Lights up while the interlock is ON.
Turns OFF when an error occurs or the control output (OSSD 1 / 2) is ON.
Turns OFF while the muting function is valid.
Lights up while the muting function is invalid.
Turns OFF while the override function is valid.
Lights up while the override function is invalid.
Lights up when the muting lamp is in normal operation.
Turns OFF when the muting lamp is in error.
Lights up when the sensor connected to the muting input terminal
(S-A) is input ON.
Lights up when the sensor connected to the muting input terminal
(S-B) is input ON.
Lights up when the sensor connected to the muting input terminal
(S-C) is input ON.
Lights up when the sensor connected to the muting input terminal
(S-D) is input ON.
Lights up when the sensor connected to the muting input terminal
(S-E) is input ON.
Lights up when the sensor connected to the muting input terminal
(S-F) is input ON.
Switches the control output to PNP output or NPN output.
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
18. Setting switches
19. Terminal block