( 7 ) Returning to factory settings

All the settings can be returned to the factory default status (preset status).
(1) If characters are displayed on the screen, press the [DISP] button to disable the character display.
(2) Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.
(3) The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed
for approx. 1 second.

7. 3 Synchro. Scan Operation

The shutter speed can be set by the horizontal scanning period (1H) or by the frame.

( 1 ) Setting by 1H

1H/525H ~ 524H/525H stands for the setting by the 1H and the shutter speed can be set by the 1H (31.8 s).
When operating Partial Scannig, the number's listed below can be used for setting.
Partial scanning OFF
90fps, E90fps
115fps, E115fps
120fps, E120fps
160fps, E160fps
180fps, E180fps
240fps, E240fps

( 2 ) Setting by the frame

2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval
specified.
(Internal VD)
RGB data
(video interval image)
FVAL
LVAL,
DAVL
24
1H/525H ~ 524H/525H
1H/348H ~ 347H/348H
1H/272H ~ 271H/272H
1H/262H ~ 261H/262H
1H/197H ~ 196H/197H
1H/175H ~ 174H/175H
1H/131H ~ 130H/131H