Returning To Factory Settings; External Sync; External Sync Signal Input Conditions; External Sync Frequency Range - Toshiba IK-HD2C Instruction Manual

Camera control unit
Table of Contents

Advertisement

9 Returning to factory settings

The contents set of each scene file can be returned to the factory default status (preset status).
(1) Select a scene file to set to the factory default status by pressing the [FILE] button.
(2) If the color bar pattern or characters are displayed on the screen, press the [DISP] button to disable the
color bar pattern and character display.
(3) Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.
(4) The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed
for approx. 1 second.

7 3 External Sync

When using the unit with an external sync signal to EXT. SYNC terminal on the rear panel.
When the external sync signal is input, the camera automatically switches its sync from the internal sync to
the external sync.
EXT. SYNC input
SYNC

1 External sync signal input conditions

SYNC 75
unbalanced

2 External sync frequency range

H : 33.716 Hz
(59.94 Hz Setting)
V : 59.94 Hz
(60 Hz Setting)
H : 33.75 Hz
V : 60 Hz

3 Using the unit with external sync signal

Adjust H (Horizontal) phase if necessary to match the output of multiple cameras.
When adjusting H (Horizontal) phase, refer to the item "7.2 (6) SYNC".
3. 1 H (Horizontal) phase adjustment
Observe the external sync signal and the video signal output
waveform of the unit with a dual trace oscilloscope, and adjust
H phase so that the H phases match.

7 4 Synchro. Scan Operation

The shutter speed can be set by the horizontal scanning period (1H).

1 Setting by 1H

1/1125H to 560/1125H stands for the setting by the 1H and the shutter speed can be set by the 1H.
Operation
External sync with SYNC
0.6 V (p-p) standard
35 ppm
35 ppm
35 ppm
35 ppm
32
Match
the phase.
External
Sync. signal
Camera
Sync. output

Advertisement

Table of Contents
loading

Table of Contents