16. REGISTRATION MODE
5.
The tare that is10% of the weight is displayed on the Tare area, and the net weight is displayed on
the Weight area, respectively. A label is issued (AUTO) or touch the [PRT/*] key (MANUAL).
TARE area
Weight area
NOTES:
1. With the initial settings, the %tare subtraction cannot be used. When you desire to use this function,
please contact the nearest TOSHIBA TEC service representative or sales agent.
2. To clear the %tare data before weighing a commodity, touch the %TARE key or Tare area. Displayed
tare and "%" will be cleared. (This function cannot be used on the CA model.)
3. After weighing a commodity and removing it together with
the container, the %tare will be automatically cleared.
4. Touching the [SAVE] key after entering the %tare retains
the %tare data even after the commodity is removed from
the platter. This function is useful when repeatedly
weighing different commodities using the same container.
In this state, "PREPACK" is displayed on the Tare area.
5. The %tare data should be entered in unit of 0.1%.
Therefore, "100" should be entered for "10%".
Acceptable %tare value is 0.0% to 99.9%, however, it
must fall within a range of 0.000 lb to 2.000 lb (US model)
or 0.000kg to 1.000 kg (CA model). Failure to do this
results in an error.
6. The above NOTES 1 to 4 are the factory default functions. When you desire to change them, please
contact the nearest TOSHIBA TEC service representative or sales agent.
Preset %Tare Subtraction
1.
Call the PLU. (e.g.: Short Ribs Boneless)
Example: Preset %tare is 5.0%
%TARE key
PRT/* key
"PREPACK"
16-22
EO1-31009
16.2 Basic Operations
SAVE key