Download Print this page

Teledyne 5800 Removal And Replacement page 6

115v refrigeration module

Advertisement

Instruction Sheet 60-4702-048 Revision H, November 8, 2019
CAUTION
Keep the module as close to the refrigerator body as
possible to avoid pulling the wiring taut and damaging
the connectors.
Line cord bushing
Figure 16: Remove refrigeration module
6. Remove the terminal cover of the compressor
(Figure 17).
Figure 17: Access compressor overload and relay
A screwdriver may be used to release the latch.
Pull module out and
rotate clockwise
Adhesive strip
7. Disconnect the three (3) compressor wires from
the power supply cable (Figure 18).
a. While holding the overload relay in place,
disconnect the brown wire.
Note
If the unit has a newer power supply with four wires
(brown, gray, black and green) refer to Step 7 in
section 216B on newer wiring instructions.
b. Disconnect the blue wire from the blue wire
on the power supply cable or the blue wire
from the capacitor and relay.
11
c. With the
/
" nut driver or socket wrench,
32
remove the nut holding the green/yellow
ground wire on the module chassis.
Fan
Figure 18: Disconnect compressor wires
8. The evaporator temperature sensor is mounted
on the sixth coil up on the evaporator
(Figure 19). Note that some older 4700 models
have a metal sensor, while current models have a
black rubber molded housing. Cut the ties
holding the evaporator sensor in place and move
it out of the frame.
Older (4700 only)
Figure 19: Remove evaporator temperature sensor
Capacitor
Brown
and relay
Black
Blue
Current (4700 & 5800)