Installing the Device
2.4 Connecting the Failsafe Alarm Relay
To mount the device to a panel, do the following:
1.
2.
2.4

Connecting the Failsafe Alarm Relay

The failsafe relay can be configured to latch based on alarm conditions. The NO
(Normally Open) contact is closed when the unit is powered and there are no ac-
tive alarms. If the device is not powered or if an active alarm is configured, the relay
opens the NO contact and closes the NC (Normally Closed) contact.
Note
Control of the failsafe relay output is configurable through RUGGEDCOM RS400F .
One common application for this relay is to signal an alarm if a power failure occurs.
For more information, refer to the RUGGEDCOM ROS Configuration Manual for the
RUGGEDCOM RS400F.
The following shows the proper relay connections.
12
Place the device against the panel and align the adapters with the mounting
holes.
1
1
Screw
1
Panel/DIN Rail Adaptor
2
Figure 2.4
Panel Mounting
Secure the device to the panel using four #6-32 screws.
RUGGEDCOM RS400F
Installation Manual, 02/2020, C79000-G8976-1341-04