Operation (manual mode)
Switching Power management on/off
Manually switch the rangehood off.
The deflector plate must be retracted.
Remove the grease filters.
The controls are accessible via the slots
for the grease filters.
Press the run-on control for
approx. 10 seconds, until the
indicator for power level 1 lights up.
Then press in turn:
- the lighting control ,
- the control, and
- then again the lighting control .
If Power management is switched on,
the 1 and B indicators light up
constantly.
When it is switched off, the 1 and B
indicators flash.
Press to switch Power
management off.
The 1 and B indicators will flash.
Press the control to switch it on.
The 1 and B indicators will light up
constantly.
Confirm the setting by pressing the
run-on control .
All the indicator lights will go out.
36
If you do not confirm your selection
within 4 minutes, the rangehood will
automatically revert to the previous
setting.