The safety address cannot be the same as (one of) the operational address(es).
Operating of these addresses results in the following:
DMX Address
Safety address
Start address
(Bubble setting)
Start address + 1
(Smoke setting)
Start address + 2
(Fan speed)
Start address + 3
(Go trigger)
When you link multiple machines with DMX, we advise you to use the same Safety
address for all machines.
CAUTION
1.7

DISPLAY PANEL

The display panel is located on the backside of the MAGICFX
Check the following menu structure for all options in the menu. Use the buttons for
navigation and selection. The left-hand LED blinks red when DMX is active. The right-
hand LED continuously lights red when an error is present.
DMX Value (decimal)
0
99
100
155
156
255
0
127
128
255
0
85
86
170
171
255
0
9
10
255
0
199
200
255
Always plug in a DMX Terminator into the DMX output of the final
unit in the control sequence. Using a DMX Terminator improves
signal reliability.
MAIN MENU
DMX/RDM SETTINGS
BACK
PREV
MAGICFX
SMOKEBUBBLE BLASTER — User and Installation Manual
®
Result
Device disabled
Device enabled
Device disabled
50 % bubble capacity
100 % bubble capacity
No smoke
50 % of bubbles contain smoke
100 % of bubbles contain smoke
Fan OFF
Minimal speed -> Full speed
Effect OFF
Effect ON
Operation of the DMX addresses