Item
Operating system setting
24. Operation
mode
For RAS-07,10,13J2AVSG-E
select table
For RAS-16J2AVSG-E
• Do cut J804 for cooling only system
Do cut J805 for heating only system
Do cut both of J804 and J805 for return
to factory default.

25. Short Timer

In the normal condition, after switching one circuit
breaker, 3-minute delay time for compressor and
1 hour for plasma air purifier are set for the
maintenance of the unit.
Operation flow and applicable data, etc.
4
1. Purpose
Choosing the operating system as
appropriate in real condition
2.
Operation
Factory default setting prefer
"Heat pump" system. Through it is
able to cooling only system heating
only system or return to factory
default.
Purpose
To start the unit immediately for the purpose of
testing, trial...etc, short timer can be used.
maintenance of the unit.
Short Timer Setting
j
Press [
k
Set the operation mode or plasma air
purifier on the remote control without
sending the signal to the unit.
l
Use the tip of the pencil to push the
[CHK] button and hold, "00" will show
on display, them press [SET] button
to make "00" disappear.
m
Press [
n
When short timer is activated, all
setting on the remote operates
immediately, besides, all indicatiors on
front panel turns ON continuously for
3
- 52 -
Description
] button to turn the unit OFF.
] button to turn the unit ON.
3 seconds.